A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical Feasibility of Deep Learning-Based Attenuation Correction Models for Tl-201 Myocardial Perfusion SPECT. | LitMetric

Purpose: We aimed to develop deep learning (DL)-based attenuation correction models for Tl-201 myocardial perfusion SPECT (MPS) images and evaluate their clinical feasibility.

Patients And Methods: We conducted a retrospective study of patients with suspected or known coronary artery disease. We proposed a DL-based image-to-image translation technique to transform non-attenuation-corrected images into CT-based attenuation-corrected (CT AC ) images. The model was trained using a modified U-Net with structural similarity index (SSIM) loss and mean squared error (MSE) loss and compared with other models. Segment-wise analysis using a polar map and visual assessment for the generated attenuation-corrected (GEN AC ) images were also performed to evaluate clinical feasibility.

Results: This study comprised 657 men and 328 women (age, 65 ± 11 years). Among the various models, the modified U-Net achieved the highest performance with an average mean absolute error of 0.003, an SSIM of 0.990, and a peak signal-to-noise ratio of 33.658. The performance of the model was not different between the stress and rest datasets. In the segment-wise analysis, the myocardial perfusion of the inferior wall was significantly higher in GEN AC images than in the non-attenuation-corrected images in both the rest and stress test sets ( P < 0.05). In the visual assessment of patients with diaphragmatic attenuation, scores of 4 (similar to CT AC images) or 5 (indistinguishable from CT AC images) were assigned to most GEN AC images (65/68).

Conclusions: Our clinically feasible DL-based attenuation correction models can replace the CT-based method in Tl-201 MPS, and it would be useful in case SPECT/CT is unavailable for MPS.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLU.0000000000005129DOI Listing

Publication Analysis

Top Keywords

attenuation correction
12
correction models
12
myocardial perfusion
12
gen images
12
images
9
models tl-201
8
tl-201 myocardial
8
perfusion spect
8
dl-based attenuation
8
evaluate clinical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!