Calculation of the total corneal astigmatism using the virtual cross cylinder method on the secondary principal plane of the cornea.

Sci Rep

Department of Ophthalmology, Osaka Minato Central Hospital, Japan Community Health care Organization (JCHO), 1-7-1 Isoji, Minato-Ku, Osaka, 552-0003, Japan.

Published: February 2024

This study aimed to establish a virtual cross cylinder method to calculate the total corneal astigmatism by combining the anterior and posterior corneal astigmatism on the secondary principal plane of the cornea based on Gaussian optics. The meridian with the least refractive power, namely, the flattest meridian of the virtual cross cylinder of a ± 0.5 × C diopter, is set as the reference meridian, and the power (F) at an angle of φ between an arbitrary meridian and the reference meridian is defined as F(φ) =  - 0.5 × C × cos2φ. The magnitude and axis of the total corneal astigmatism were calculated by applying trigonometric functions and the atan2 function based on the combination of the virtual cross cylinders of the anterior corneal astigmatism and the posterior corneal astigmatism. To verify the performance of the virtual cross cylinder method, a verification experiment with two Jackson cross cylinders and a lensmeter was performed, and the measured and calculated values were compared. The limit of the natural domain of the arctangent function is circumvented by using the atan2 function. The magnitude and axis of the total corneal astigmatism are determined through generalized mathematical expressions. The verification experiment results showed good agreement between the measured and calculated values. Compared to the vector analysis method, the virtual cross cylinder method is mathematically sound and straightforward. A novel technique for calculating total corneal astigmatism, the virtual cross cylinder method, was developed and verified.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310508PMC
http://dx.doi.org/10.1038/s41598-024-55154-xDOI Listing

Publication Analysis

Top Keywords

corneal astigmatism
32
virtual cross
28
cross cylinder
24
total corneal
20
cylinder method
20
corneal
8
astigmatism
8
astigmatism virtual
8
cross
8
secondary principal
8

Similar Publications

Distinct Ocular Surface Microbiome in Keratoconus Patients Correlate With Local Immune Dysregulation.

Invest Ophthalmol Vis Sci

January 2025

GROW Research Laboratory, Narayana Netralaya Foundation, Bangalore, India.

Purpose: Keratoconus (KC) is characterized by irregular astigmatism along with corneal stromal weakness and is associated with altered immune status. Tissue resident microbiomes are known to influence the immune status in other organs, but such a nexus has not been described in ocular conditions. Therefore, we examined the ocular surface microbiome of patients with KC and correlated it to the immune cell and tear molecular factor profiles.

View Article and Find Full Text PDF

Purpose: To determine the performance of TOTAL30 for Astigmatism (T30fA; Alcon; Fort Worth, TX, USA) contact lenses (CLs) in existing CL wearers who are also frequent digital device users.

Methods: This 1-month, 3-visit study recruited adult, 18- to 40-year-old subjects who were required to use daily digital devices for at least 8 hours per day. All subjects were refit into T30fA CLs.

View Article and Find Full Text PDF

Baseline and outcome stereoacuity of children with anisometropic amblyopia undergoing dichoptic amblyopia treatment.

J AAPOS

January 2025

Pediatric Vision Laboratory, Retina Foundation of the Southwest, Dallas, Texas; Optometry & Vision Science, University of Waterloo, Waterloo, Ontario, Canada.

Background: One rationale for dichoptic amblyopia therapy is that it may promote recovery of binocular function. Yet data on binocular outcomes in anisometropic amblyopia following dichoptic therapy are sparse. We report factors associated with pre- and post-treatment binocular function in anisometropic amblyopia, and examine binocular function in children who recover normal visual acuity compared to those with residual amblyopia.

View Article and Find Full Text PDF

Purpose To determine the corneal topographic characteristics of children with blepharokeratoconjunctivitis (BKC), a chronic inflammatory ocular surface disease involving the lid margin, conjunctiva, and cornea. Methods The corneal topography of 21 children diagnosed with BKC between March 2008 and June 2019 at a single institution were reviewed retrospectively. Pachymetry and asymmetry indices were also analyzed.

View Article and Find Full Text PDF

Background: Strabismus is a potential cause of ocular morbidity.

Objective: The aim of this study was to determine the frequency, types of manifest strabismus and co-morbidities among patients attending a referral paediatric ophthalmology and strabismus clinic in Calabar, Nigeria.

Methods: A retrospective review of case-notes of patients attending the paediatric ophthalmology and strabismus clinic from January 1, 2017 to December 31, 2019 was done.

View Article and Find Full Text PDF