Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Galactosemia is an inherited disease that occurs as a result of insufficient or no synthesis of some enzymes (GALT, GALK, and GALE) in galactose metabolism. Failure to make an early diagnosis, especially in newborns, can lead to severe clinical and even fatal consequences. The aim of this study is to develop a biosensor for measuring free galactose in plasma. The immobilization components of the developed free galactose biosensor are screen printed carbon electrode (SCPE), Prussian blue (PB), chitosan (CHIT), Nafion (NAF), gold nanoparticle (GNP), and galactose oxidase (GaOX). The CHIT/GaOX/NAF-GNP/GaOX/CHIT-GNP/SCPE-PB electrode showed a sensitive amperometric response to detect galactose. While the surface characterization of the biosensor was performed with cyclic voltammetry and scanning electron microscopy, the optimization and performance characterizations were made by applying an amperometry technique. The amperometric operating potential for the free galactose biosensor was determined as -0.05 V. The linear detection range for the free galactose biosensor is between 0.025 and 10 mM. This range includes galactose levels in plasma of both healthy and patients. The percent coefficient of variation values calculated for intraday and interday repeatability of the developed biosensor are below 10%. The practical use of the biosensor, for which optimization and characterization studies were carried out, was tested in 10 healthy 11 patients with galactosemia, and the results were compared with the colorimetric method. In conclusion, the unique analytical properties and effortless preparation of the new galactose biosensor developed in this study make them serious candidates for point-of-care diagnostic testing.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10882682 | PMC |
http://dx.doi.org/10.1021/acsomega.3c06789 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!