A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Usefulness of the Distribution of Relaxation Time Method in Electroanalytical Systems: The Case of Voltammetric Ion-Selective Electrodes. | LitMetric

Usefulness of the Distribution of Relaxation Time Method in Electroanalytical Systems: The Case of Voltammetric Ion-Selective Electrodes.

ACS Omega

Deparment of Chemistry, School of Engineering Science in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 30, SE-100 44 Stockholm, Sweden.

Published: February 2024

AI Article Synopsis

  • The distribution of relaxation time (DRT) method offers better insights into electrochemical processes compared to traditional electrochemical impedance spectroscopy (EIS), but its application in electroanalytical systems has been limited.
  • Researchers explore the DRT method to analyze EIS data from solid-state voltammetric ion-selective electrodes, focusing on the impact of a thin permselective membrane on a conducting polymer's doping mechanism.
  • The study reveals multiple electrochemical processes associated with charge-transfer doping in the polymer, demonstrating how the EIS-DRT combination can enhance understanding of complex charge-transfer events beyond the capabilities of conventional methods.

Article Abstract

Despite the distribution of relaxation time (DRT) method providing clear insights about processes that go unnoticed by traditional electrochemical impedance spectroscopy (EIS) analysis, it has not yet been adopted to solve electroanalytical systems. As an illustration case, we apply the DRT method to deconvolve EIS data from solid-state voltammetric ion-selective electrodes (ISEs). The main aim is to shed light on the underlying working mechanism across the different materials and interfaces, specifically, the doping of a conducting polymer when covered with a very thin (ca. 230 nm) permselective membrane. Although frequency-dependent AC measurements in EIS allow the separation of processes that contribute to the electrical signal, interpretation of the data is challenging. DRT may overcome this inconvenience by revealing a series of peaks corresponding to the predominant electrochemical processes, without any preknowledge on those. To demonstrate our hypothesis, we examine the conducting polymer poly(3-octylthiophene) (POT) linked to a membrane with sodium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate (NaTFPB) as the cation exchanger, in which the lipophilic anionic part (TFPB) is responsible for the POT doping when it gets electrochemically oxidized (POT). The investigation of EIS data obtained under different conditions with the DRT method showed the occurrence of several processes. We have attributed two of these to two different conformational changes in the POT film in connection with p-type charge-transfer doping. Indeed, the kinetics is found to follow a Butler-Volmer behavior, with average charge transfers of 0.5 and 0.3 mol of electrons for each peak. Overall, we demonstrate the utility of the EIS-DRT tandem to separately study charge-transfer events that interconnect along the same (interfacial segmented) system, which cannot be reached by using classical electrochemical approaches. These kinds of insights are necessary for a more efficient design and high-level exploitation of voltammetric ISEs but also other electrochemical systems such as catalysts, batteries, and photovoltaic cells.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10882611PMC
http://dx.doi.org/10.1021/acsomega.3c08656DOI Listing

Publication Analysis

Top Keywords

drt method
12
distribution relaxation
8
relaxation time
8
electroanalytical systems
8
voltammetric ion-selective
8
ion-selective electrodes
8
eis data
8
conducting polymer
8
method
4
time method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!