The decolorization of the Basic violet I (BVI) dye when interacted with a corona discharge is studied in the present work, taking in account two systems, batch and flux. The current and voltage were measured during the whole process in which a corona plasma was generated, with an applied power of 51.9 and 167.72 W where the transport gas was air. A batch reactor and a flow reactor were used, where 500 and 5000 mL of samples were treated, respectively. Optical emission spectra (OES) were measured where the oxidizing species ·OH were at wavelengths of 307.597 and 310.148 nm, associated with the A∑ - XΠ transition. The absorption spectra for the batch system showed a discoloration of 85.7% in the first 10 min, while in the flow system, the absorption was 93.9% at the same time and 4.5% at the same time by conventional heating. Characteristics of the final sample included an acidic solution with an electrical conductivity of 449.20 ± 55.44 and 313.6 ± 39.58 μS/cm, a dissolved oxygen concentration of 7.74 ± 0.2 and 6.37 ± 0.23 mg/L, an absorbance of 0.04 ± 0.01 and 0.03 ± 0.01 au, with turbidity measuring 1.22 ± 1.59 and 10.34 ± 4.96 NTU, and an energy cost of 1.1 × 10 and 6.3 × 10 g/kWh in the batch and continuous flow systems, respectively. The interaction of the corona plasma with water promoted the production of reactive species, resulting in the discoloration of the Basic Violet I dye.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10882621PMC
http://dx.doi.org/10.1021/acsomega.3c07559DOI Listing

Publication Analysis

Top Keywords

basic violet
12
corona plasma
12
violet bvi
8
flow systems
8
batch
5
physical-chemical assessment
4
assessment azo
4
azo dye
4
dye basic
4
bvi discoloration
4

Similar Publications

Surface-enhanced Raman scattering (SERS) technology has attracted more and more attention due to its high sensitivity, low water interference, and quick measurement. Constructing high-performance SERS substrates with high sensitivity, uniformity and reproducibility is of great importance to put the SERS technology into practical application. In this paper, we report a simple fabrication process to construct dense silver-coated PMMA nanoparticles-on-a-mirror SRES substrates.

View Article and Find Full Text PDF

Antimicrobial Responses to Bacterial Metabolic Activity and Biofilm Formation Studied Using Microbial Fuel Cell-Based Biosensors.

Biosensors (Basel)

December 2024

Fujian Key Laboratory of Translational Research in Cancer and Neurodegenerative Diseases, School of Basic Medical Sciences, Fujian Medical University, Fuzhou 350108, China.

Simultaneous monitoring of antimicrobial responses to bacterial metabolic activity and biofilm formation is critical for efficient screening of new anti-biofilm drugs. A microbial fuel cell-based biosensor using as an electricigen was constructed. The effects of silver nanoparticles (AgNPs) on the cellular metabolic activity and biofilm formation of in the biosensors were investigated and compared with the traditional biofilm detection method.

View Article and Find Full Text PDF
Article Synopsis
  • Lichong decoction (LD) is an effective and safe treatment for uterine leiomyoma (ULM) based on traditional Chinese medicine, though the exact mechanisms of its effects aren't fully understood.
  • The study aimed to investigate how LD improves ULM by analyzing its impact on cell viability, apoptosis, and gene expression, along with tests using a rat ULM model.
  • Results indicated that LD reduced cell viability and induced apoptosis in ULM cells, and it was found to decrease fibrosis and inflammation by inhibiting the CXCL8/PI3K/AKT pathway, highlighting several bioactive compounds in LD that may contribute to its therapeutic effects.
View Article and Find Full Text PDF

A label-free fluorescent-hydrogel sensor for heparin detection in diluted whole blood.

Chem Commun (Camb)

December 2024

Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China.

Heparin is a widely used blood anticoagulant and its monitoring in blood is essential during surgery. Unavoidable interference factors such as blood color and luminescence can interfere with the fluorescence visualization of heparin. Herein, we found a ratiometric fluorescence probe consisting of SYBR green and cresyl violet responsive to heparin mainly based on electrostatic interactions.

View Article and Find Full Text PDF

Background: Epstein-Barr virus (EBV) infection increases the risk of having multiple sclerosis (MS). Data on adults with myelin oligodendrocyte glycoprotein antibody-associated disease (MOGAD) are lacking.

Objective: To compare EBV serological status in MOGAD versus MS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!