A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multi-functional voltage and current based enhancement of power quality in grid-connected microgrids considering harmonics. | LitMetric

The introduction of a renewable energy source (RES) based multi-functional grid-tied inverter (MFGTI) stands as a favorable remedy for addressing power quality concerns within distributed generation (DG) systems and microgrids. Nonetheless, the effectiveness of a traditional MFGTI will be restricted in addressing power quality issues based on voltage. The presented research proposes a novel structure for MFGTI to enhance power quality concerns associated with voltage, current, and harmonic distortions resulting from both grid and loads. Based on this strategy, the introduced MFGTI can be linked with the grid by bidirectional switches either in a parallel or series. This feature provides various operational conditions in response to diverse disruptions in the grid. To effectively adjust the voltage, current and voltage reduction are determined through mathematical analysis, considering both the grid conditions and the load requirements. Furthermore, this strategy offers different compensation strategies, control schemes, and transition modes in the MFGTI. The major disturbances such as unbalanced and balanced voltage swell/sag, harmonics, and interruption are compensated. The shunt compensation controller is based on a second order sequence filter (SOSF) to provide the load current active component. A damping PI regulator based series compensation controller is presented for the voltage swell/sag reduction. Moreover, a new three level hierarchical control is proposed in which a droop control for compensating the interruption and a decouple dual synchronous reference frame (DDSRF) for compensating the unbalanced voltage sag/swell are utilized. The simulations in the MATLAB/SIMULINK show that using the proposed compensation strategies, the proposed MFGTI can compensate effectively the different disturbances through changing the transition states by the proposed algorithm based bidirectional switches.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10884810PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e26008DOI Listing

Publication Analysis

Top Keywords

power quality
16
voltage current
12
addressing power
8
quality concerns
8
bidirectional switches
8
compensation strategies
8
voltage swell/sag
8
compensation controller
8
based
7
voltage
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!