Background: The in vitro specific IgE (sIgE) assays now commonly used in clinical laboratories are not only time-consuming and expensive but also require many serum samples. To address these limitations, a novel fluorescent microsphere-based multiplex flow cytometric immunoassay was developed. This innovative assay enables rapid and simultaneous quantitative detection of multiple allergen-sIgE antibodies.

Objective: To establish a new method for the simultaneous quantitative detection of 6 allergen-sIgE antibodies based on fluorescence multiplex flow cytometry.

Methods: Six different encoded fluorescent microspheres were selected to covalently couple 6 allergens, and their antigen-coupling activities were verified. After optimizing the multiplexing procedure and reaction conditions, including the concentration of microspheres encapsulated by allergens, reaction temperature, and reaction time, standard curves were established to quantify the 6 allergen-sIgE, and their performance was evaluated according to clinical guidelines.

Results: The chosen analytical mode was optimized for the detection of the 6 allergens-sIgE for 70 minutes. The established coefficients of variation for multiplex flow cytometry reproducibility and intermediate precision were less than 10%. Linear regression analysis showed a highly significant quantitative correlation between the results of the multiple analyses of Dermatophagoides pteronyssinus, Dermatophagoides farinae, Artemisia, and cat hair allergens and ImmunoCAP (Thermo Fisher Scientific): the r values ranged from 0.85 to 0.97 (P < .0001). In addition, there was a high correlation between the results of the multiplex analysis of dog hair allergens and the capture enzyme-linked immunosorbent assay (r = 0.92, P < .0001).

Conclusion: A high-throughput system called multiplex flow cytometry has been developed for the simultaneous detection of 6 inhalant allergens. The method has the advantage of being rapid and using less serum. Furthermore, it has the potential to be expanded to include other allergens and biologic agents.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.anai.2024.02.018DOI Listing

Publication Analysis

Top Keywords

multiplex flow
16
simultaneous quantitative
12
quantitative detection
12
cytometric immunoassay
8
detection allergen-sige
8
allergen-sige antibodies
8
flow cytometry
8
hair allergens
8
allergens
6
detection
5

Similar Publications

Stacking paper sheets into multi-purpose quick response sensing code with built-in nitrocellulose-membrane-free lateral flow assay for detecting tetracycline in food samples.

Food Chem

January 2025

State Key Laboratory of Pulp and Paper Engineering, School of Light Industry and Engineering, South China University of Technology, Guangzhou 510640, China; Guangdong Provincial Key Laboratory of Plant Resources Biorefinery, Guangzhou 510006, China. Electronic address:

Lateral flow assays (LFAs) have found extensive applications in food safety and quality monitoring. Now, smartphone technology is redefining how tests are conducted at the point of use. At the same time, quick response (QR) codes enhance digital connectivity for information transmission, data collection, and response linkage.

View Article and Find Full Text PDF

Background: Post-coronavirus disease 19 lung fibrosis (PCLF) shares common immunological abnormalities with idiopathic pulmonary fibrosis (IPF), characterized by an unbalanced cytokine profile being associated with the development of lung fibrosis. The aim of the present study was to analyze and compare the different subsets of CD4- and CD8-T cells, along with specific cytokine expression patterns, in peripheral blood (PB) from patients affected by PCLF and IPF and healthy controls (HCs).

Methods: One-hundred patients followed at the Rare Lung Disease Center of Siena University Hospital were enrolled.

View Article and Find Full Text PDF

Background: is a gram-negative pathogen. The infection caused by this pathogen may result in gastritis and can increase the risk of gastric cancer. This study investigated the relationship between infection as the main risk factor for gastritis and changes in serum inflammatory cytokine levels.

View Article and Find Full Text PDF

The discovery of broadly protective antibodies to the influenza virus neuraminidase (NA) has raised interest in NA as a vaccine target. However, recombinant, solubilized tetrameric NA ectodomains are often challenging to express and isolate, hindering the study of anti-NA humoral responses. To address this obstacle, we established a panel of 22 non-adherent cell lines stably expressing native, historical N1, N2, N3, N9, and NB NAs anchored on the cell surface.

View Article and Find Full Text PDF

Digital microfluidic platform for dried blood spot newborn screening of lysosomal storage diseases in Campania region (Italy): Findings from the first year pilot project.

Mol Genet Metab

December 2024

Department of Molecular Medicine and Medical Biotechnology, Medical School, University of Naples Federico II, 80131 Naples, Italy; CEINGE-Biotecnologie Avanzate Franco Salvatore s.c.ar.l., 80145 Naples, Italy. Electronic address:

Background: Newborn screening (NBS) is a simple, non-invasive test that allows for the early identification of genetic diseases within the first days of a newborn's life. The aim of NBS is to detect potentially fatal or disabling conditions in newborns as early as possible, before the onset of disease symptoms. Early diagnosis enables timely treatments and improves the quality of life for affected patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!