A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

UPLC-Orbitrap-HRMS application for analysis of plasma sterols. | LitMetric

Correct identification and quantification of different sterol biomarkers can be used as a first-line diagnostic approach for inherited metabolic disorders (IMD). The main drawbacks of current methodologies are related to lack of selectivity and sensitivity for some of these compounds. To address this, we developed and validated two sensitive and selective assays for quantification of six cholesterol biosynthesis pathway intermediates (total amount (free and esterified form) of 7-dehydrocholesterol (7-DHC), 8-dehydrocholesterol (8-DHC), desmosterol, lathosterol, lanosterol and cholestanol), two phytosterols (total amount (free and esterified form) of campesterol and sitosterol) and free form of two oxysterols (7-ketocholesterol (7-KC) and 3β,5α,6β-cholestane-triol (C-triol). For quantification of four cholesterol intermediates we based our analytical approach on sterol derivatization with 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD). Quantification of all analytes is performed using UPLC coupled to an Orbitrap high resolution mass spectrometry (HRMS) system, with detection of target ions through full scan acquisition using positive atmospheric pressure chemical ionization (APCI) mode. UPLC and MS parameters were optimized to achieve high sensitivity and selectivity. Analog stable isotope labeled for each compound was used for proper quantification and correction for recovery, matrix effects and process efficiency. Precision (2.4%-12.3% inter-assay variation), lower limit of quantification (0.027 nM-50.5 nM) and linearity (5.5 μM (R 0.999) - 72.3 μM (R 0.997)) for phyto- and oxysterols were determined. The diagnostic potential of these two assays in a cohort of patients (n = 31, 50 samples) diagnosed with IMD affecting cholesterol and lysosomal/peroxisomal homeostasis is demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2024.342347DOI Listing

Publication Analysis

Top Keywords

quantification cholesterol
8
total amount
8
amount free
8
free esterified
8
esterified form
8
quantification
6
uplc-orbitrap-hrms application
4
application analysis
4
analysis plasma
4
plasma sterols
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!