A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Weld-free mounting of lamellae for electrical biasing operando TEM. | LitMetric

Weld-free mounting of lamellae for electrical biasing operando TEM.

Ultramicroscopy

Advanced Electron Microscopy Division, Institute of Materials Science, Technische Universität Darmstadt, Peter-Grünberg-Straße 2, Darmstadt 64287, Germany. Electronic address:

Published: June 2024

Recent advances in microelectromechanical systems (MEMS)-based substrates and sample holders for in situ transmission electron microscopy (TEM) are currently enabling exciting new opportunities for the nanoscale investigation of materials and devices. The ability to perform electrical testing while simultaneously capturing the wide spectrum of signals detectable in a TEM, including structural, chemical, and even electronic contrast, represents a significant milestone in the realm of nanoelectronics. In situ studies hold particular promise for the development of Metal-Insulator-Metal (MIM) devices for use in next-generation computing. However, achieving successful device operation in the TEM typically necessitates meticulous sample preparation involving focused ion beam (FIB) systems. Conducting contamination introduced during the FIB thinning process and subsequent attachment of the sample onto a MEMS-based chip remains a formidable challenge. This article delineates an improved FIB-based sample preparation methodology that results in good electrical connectivity and operational functionality across various MIM devices. To exemplify the efficacy of the sample preparation technique, we demonstrate preparation of a clean cross section extracted from a Au/Pt/BaSrTiO/SrMoO tunable capacitor (varactor). The FIB-prepared TEM lamella mounted on a MEMS-based chip showed current levels in the tens of picoamperes range at 0.1 V. Furthermore, the electric response and current density of the TEM lamella device closely align with macro-scale devices. These samples exhibit comparable current densities to their macro-sized counterparts thus validating the sample preparation process and confirming device connectivity. The simultaneous operation and TEM characterization of electronic devices enabled by this process enables direct correlation between device structure and function, which could prove pivotal in the development of new MIM systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2024.113939DOI Listing

Publication Analysis

Top Keywords

sample preparation
16
mim devices
8
operation tem
8
mems-based chip
8
tem lamella
8
tem
7
sample
6
devices
5
preparation
5
weld-free mounting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!