Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.29319DOI Listing

Publication Analysis

Top Keywords

editorial "reproducibility
4
"reproducibility repeatability
4
repeatability intravoxel
4
intravoxel incoherent
4
incoherent motion
4
motion mri
4
mri acquisition
4
acquisition methods
4
methods liver"
4
editorial
1

Similar Publications

The Morris Water Maze (MWM) is the most commonly used assay for evaluating learning and memory in laboratory mice. Despite its widespread use, contemporary reviews have highlighted substantial methodological variation in experimental protocols and that the associated testing procedures are acutely (each trial) and chronically (testing across days) stressful; stress impairs attention, memory consolidation and the retrieval of learned information. Moreover, the interpretation of behavior within the MWM is often difficult because of wall hugging, non-spatial swim strategies, floating, and jumping off the escape platform.

View Article and Find Full Text PDF

Background: Brain connectome fingerprinting represents a recent and valid approach in assessing individual identifiability on the basis of the subject-specific brain functional connectome. Although this methodology has been tested and validated in several neurological diseases, its performance, reliability and reproducibility in healthy individuals has been poorly investigated. In particular, the impact of the changes in brain connectivity, induced by the different phases of the menstrual cycle (MC), on the reliability of this approach remains unexplored.

View Article and Find Full Text PDF

Diminishing restrictive practices in psychiatric wards virtual reality training: Old wine in a new bottle?

World J Psychiatry

December 2024

Department of Gastroenterology, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.

This editorial examines the application of virtual reality (VR) training to mitigate restrictive practices (RPs) within psychiatric facilities. RPs include physical restraints, seclusion, and chemical restraints, used to ensure patient safety but with varying usage rates across regions. In recent years, there has been a growing focus on the adverse effects of RPs on both healthcare workers and patients, leading to calls for its reduction.

View Article and Find Full Text PDF

Background: Dixon-based magnetic resonance imaging (MRI) intramuscular proton density fat fraction (PDFF) is a potentially useful imaging biomarker of muscle quality. However, multi-vendor, multi-site reproducibility of intramuscular PDFF quantification, required for large clinical studies, can be strongly dependent on acquisition and processing. The purpose of this study was (I) to develop a 6-point Dixon MRI-based acquisition and processing technique for reproducible multi-vendor, multi-site quantification of thigh intramuscular PDFF; and (II) to evaluate the ability of the technique to detect differences in thigh muscle status between operated .

View Article and Find Full Text PDF

Purpose: Evaluate the feasibility of quantification of Relaxation Along a Fictitious Field in the 2nd rotating frame (RAFF2) relaxation times in the human myocardium at 3 T.

Methods: mapping was performed using a breath-held ECG-gated acquisition of five images: one without preparation, three preceded by RAFF2 trains of varying duration, and one preceded by a saturation prepulse. Pixel-wise maps were obtained after three-parameter exponential fitting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!