Purpose: To evaluate the Schlemm's canal (SC) parameters obtained by swept-source optical coherence tomography (OCT) different in Graves' ophthalmopathy (GO) eyes compared to healthy eyes.

Methods: This cross-sectional observational study evaluated 64 eyes of 32 GO cases and 56 eyes of 28 healthy controls. The study was conducted between October 2020 and June 2021. SC images were obtained from the temporal limbus of individuals using swept-source OCT. SC length (SCL) and SC area (SCA) were measured. The relationship between SC parameters in the patient group and intraocular pressure (IOP), retinal nerve fiber layer (RNFL) thickness, Graves' disease (GD) duration, and clinical activity score (CAS) was evaluated.

Results: In the GO group, 64 eyes of 32 patients were evaluated, and in the age and gender-matched healthy control group, 56 eyes of 28 individuals were assessed. SC images from 4 eyes of 4 patients in the patient group and 1 eye of 1 patient in the control group were not clear, preventing SCL and SCA measurements for these eyes. SCL and SCA measurements were found to be lower, and IOP and Hertel values were higher in the GO group compared to the healthy controls. However, no significant correlation was observed between SCL and SCA with IOP, RNFL thickness, GD duration, GO duration, or CAS in the GO group. In the GO group, the mean value of SCA was found to be higher in eyes with glaucoma or OHT compared to those without.

Conclusion: These findings indicate that SC in GO-affected eyes is shorter and has a smaller area than in healthy individuals. Additionally, higher IOP and Hertel values were observed in the GO group compared to healthy controls. This study suggests that assessing SC using anterior segment OCT could provide valuable insights into the regulation of IOP and the development of glaucoma in GO-affected eyes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11222225PMC
http://dx.doi.org/10.1007/s00417-024-06397-xDOI Listing

Publication Analysis

Top Keywords

compared healthy
12
healthy controls
12
scl sca
12
eyes
10
group
9
schlemm's canal
8
swept-source optical
8
optical coherence
8
coherence tomography
8
graves' ophthalmopathy
8

Similar Publications

Purpose: The optic nerve (ON) is mechanically perturbed by eye movements that shift cerebrospinal fluid (CSF) within its surrounding dural sheath. This study compared changes in ON length and CSF volume within the intraorbital ON sheath caused by eye movements in healthy subjects and patients with optic neuropathies.

Methods: Twenty-one healthy controls were compared with 11 patients having primary open angle glaucoma (POAG) at normal intraocular pressure (IOP), and 11 with chronic non-arteritic anterior ischemic optic neuropathy (NA-AION).

View Article and Find Full Text PDF

Purpose Of Review: Chronic pain is highly prevalent and involves a complex interaction of sensory, emotional, and cognitive processes, significantly influenced by ambient temperature. Despite advances in pain management, many patients continue to experience inadequate pain relief. This review aims to consolidate and critically evaluate the current evidence on the impact of ambient temperature on chronic pain conditions such as fibromyalgia (FM), multiple sclerosis (MS), complex regional pain syndrome (CRPS), and osteoarthritis (OA).

View Article and Find Full Text PDF

Cine magnetic resonance imaging (Cine-MRI) may evaluate the swallowing function and locations of patients with dysphagia, which requires very fast imaging speed. Compressed sensing is a technique that allows for faster MRI imaging by sampling fewer data points and reconstructing the image via optimization techniques, crucial for capturing the rapid movements involved in swallowing. This study aimed to analyze swallowing function and locations in patients with head and neck cancer and healthy individuals using Cine-MRI based on compressed sensing.

View Article and Find Full Text PDF

This study aimed to evaluate the hemodynamic and ventricular performance of neonates with hypoxic-ischemic encephalopathy (HIE) undergoing therapeutic hypothermia using conventional and advanced echocardiographic techniques. This observational, prospective study included 22 neonates with HIE matched with 22 healthy neonates. Echocardiographic studies were performed 24 h after achieving target temperature during hypothermia and 24 h after rewarming.

View Article and Find Full Text PDF

: Cardiovascular diseases (CVDs) remain a leading cause of morbidity and mortality worldwide, with dietary interventions showing promise in reducing CVD risk factors. Phytosterols (PSs) in plant-based foods may reduce CVD risk by lowering low-density lipoprotein cholesterol. However, the relationship between dietary PS intake and CVD outcomes remains inconclusive.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!