This paper presents the design and development of a high-resolution 3D ultrasound imaging system based on a 1 × 256 piezoelectric ring array, achieving an accuracy of 0.1 mm in both ascending and descending modes. The system achieves an imaging spatial resolution of approximately 0.78 mm. A 256 × 32 cylindrical sensor array and a digital phantom of breast tissue were constructed using the k-Wave toolbox. The signal is acquired layer by layer using 3D acoustic time-domain simulation, resulting in the collection of data from each of the 32 layers. The 1 × 256 ring array moves on a vertical trajectory from the chest wall to the nipple at a constant speed. A data set was collected at intervals of 1.5 mm, resulting in a total of 32 data sets. Surface rendering and volume rendering algorithms were used to reconstruct 3D ultrasound images from the volume data obtained via simulation so that the smallest simulated reconstructed lesion had a diameter of 0.3 mm. The reconstructed three-dimensional image derived from the experimental data exhibits the contour of the breast model along with its internal mass. Reconstructable dimensions can be achieved up to approximately 0.78 mm. The feasibility of applying the system to 3D breast ultrasound imaging has been demonstrated, demonstrating its attributes of resolution, precision, and exceptional efficiency.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10891686 | PMC |
http://dx.doi.org/10.3390/mi15020209 | DOI Listing |
Thyroid
January 2025
Division of Endocrinology, Diabetes and Metabolism, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
In the era of molecular testing, thyroid nodules with indeterminate cytology are increasingly being managed nonoperatively. The false-negative rates of these molecular tests, and therefore missed malignancies, are not well defined in real-world clinical practice. This retrospective study of patients undergoing fine needle aspiration (FNA) biopsy at our health system between November 2017 and March 2022 included nodules with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) III and IV cytology and negative, currently negative, or negative but limited ThyroSeq version 3 (TSv3) results.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Ophthalmology, Gavin Herbert Eye Institute, University of California Irvine, Irvine, California, United States of America.
Purpose: This study aims to explore the feasibility and performance of three-dimensional ultrasound (3DUS) imaging in ophthalmology using commercially available ultrasound probes adapted to a slit lamp.
Significance: Despite ultrasound's long-standing application in eye care for visualizing ocular components, the evolution of 3DUS technology has remained inactive, with limited development and commercial availability. This study introduces a novel method that could potentially enhance ophthalmic diagnostics and treatment planning by providing comprehensive 3D views of ocular structures using existing ultrasound probes adapted to the conventional slit lamp.
Wiad Lek
January 2025
MUNICIPAL NONPROFIT ENTERPRISE «TERNOPIL REGIONAL CLINICAL HOSPITAL», TERNOPIL REGIONAL RADA, TERNOPIL, UKRAINE.
Objective: Aim: To study the ATFL length among asymptomatic population of young patients on both joints by using the method of ultrasound examination of the ankle joint and applying the inversion stress test.
Patients And Methods: Materials and Methods: the length of the ATFL was measured among 60 boys and 60 girls during the research. Sonography was performed on both joints, in each of the two studied positions, three times per position in order to obtain the average ligament length.
Ann Rheum Dis
January 2025
Department of Medicine 3-Rheumatology and Immunology, Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg and Uniklinikum Erlangen, Erlangen, Germany; Deutsches Zentrum Immuntherapie (DZI), Friedrich-Alexander-Universität (FAU) Erlangen-Nürnberg and Uniklinikum Erlangen, Erlangen, Germany, Erlangen, Germany. Electronic address:
Objectives: CD19-targeting chimeric antigen receptor (CAR) T-cell therapy can induce long-term drug-free remission in patients with autoimmune diseases (AIDs). The efficacy of CD19-CAR T-cell therapy is presumably based on deep tissue depletion of B cells; however, such effect has not been proven in humans in vivo.
Methods: Sequential ultrasound-guided inguinal lymph node biopsies were performed at baseline and after CD19-CAR T-cell therapy in patients with AIDs.
J Am Podiatr Med Assoc
January 2025
¶Department of Medicine, Division of Rheumatology, Firat University, Elazig, Turkey.
Background: Many factors, such as decreased spinal mobility, pain, and dysfunction can affect gait parameters in patients with ankylosing spondylitis. The purpose of this study was to investigate the effects of plantar fascia enthesitis and disease-specific measurements on gait parameters in patients with ankylosing spondylitis.
Methods: The Win-Track platform was used to evaluate spatiotemporal parameters in patients with ankylosing spondylitis and in healthy controls.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!