(1) Background: Structural remodeling plays an important role in the pathophysiology of atrial fibrillation (AF). It is likely that structural remodeling occurs transmurally, giving rise to electrical endo-epicardial asynchrony (EEA). Recent studies have suggested that areas of EEA may be suitable targets for ablation therapy of AF. We hypothesized that the degree of EEA is more pronounced in areas of transmural conduction block (T-CB) than single-sided CB (SS-CB). This study examined the degree to which SS-CB and T-CB enhance EEA and which specific unipolar potential morphology parameters are predictive for SS-CB or T-CB. (2) Methods: Simultaneous endo-epicardial mapping in the human right atrium was performed in 86 patients. Potential morphology parameters included unipolar potential voltages, low-voltage areas, potential complexity (long double and fractionated potentials: LDPs and FPs), and the duration of fractionation. (3) Results: EEA was mostly affected by the presence of T-CB areas. Lower potential voltages and more LDPs and FPs were observed in T-CB areas compared to SS-CB areas. (4) Conclusion: Areas of T-CB could be most accurately predicted by combining epicardial unipolar potential morphology parameters, including voltages, fractionation, and fractionation duration (AUC = 0.91). If transmural areas of CB indeed play a pivotal role in the pathophysiology of AF, they could theoretically be used as target sites for ablation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10889286 | PMC |
http://dx.doi.org/10.3390/jcm13041015 | DOI Listing |
Chem Sci
December 2024
Key Laboratory of Bio-inspired Materials and Interfacial Science, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences Beijing 100190 China
Nanofluidics is a system of fluid transport limited to a nano-confined space, including the transport of ions and molecules. The use of intelligent nanofluidics has shown great potential in energy conversion. However, ion transport is hindered by homogeneous membranes with uniform charge distribution and concentration polarization, which often leads to an undesirable power conversion performance.
View Article and Find Full Text PDFFront Psychiatry
December 2024
Service of Old Age Psychiatry, Department of Psychiatry, Lausanne University Hospital and University of Lausanne, Prilly, Switzerland.
Introduction: Major depressive disorder (MDD) exhibits heterogeneity in treatment response.
Objective: This exploratory analysis aims to evaluate the differential changes in individual items of the MADRS between melancholic MDD (M-MDD) and unspecified MDD (U-MDD) following electroconvulsive therapy (ECT).
Methods: The study included 23 patients with unipolar MDD who received ECT.
Photoacoustics
June 2024
Photoacoustics and Ultrasound Laboratory Eindhoven (PULS/e), Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, 5600 MB, The Netherlands.
Photoacoustic imaging creates light-induced ultrasonic signals to provide valuable information on internal body structures and tissue morphology non-invasively. A multi-aperture photoacoustic imaging (MP-PAI) system is an improvement over conventional photoacoustic imaging (PAI) systems in terms of resolution, contrast, and field of view. Previously, a prototype MP-PAI system was introduced based on multiple capacitive micromachined ultrasound transducers (CMUTs) with shared channels, such that each element in a CMUT shares its channel with its counterpart in other CMUTs.
View Article and Find Full Text PDFFront Cardiovasc Med
November 2024
Arrhythmia Center, The First Affiliated Hospital of Ningbo University, Ningbo, China.
Background: It remains unclear whether the current recommended ablation index (AI) value is suitable for individualized catheter ablation. Prior research has established that the elimination of the negative component of the unipolar electrogram (UP-EGM) applications reflects the formation of transmural lesion during radiofrequency ablation. The aim of this study was to explore the relationship between AI values when UP-EGM turns positive during pulmonary vein isolation and recommended AI values.
View Article and Find Full Text PDFAnn Cardiothorac Surg
November 2024
Translational Electrophysiology Lab, Department of Cardiology, Erasmus Medical Center, Rotterdam, The Netherlands.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!