Development and Comparison of Treatment Decision Tools for Glucocorticoid-Induced Osteoporosis.

Diagnostics (Basel)

Division of Rheumatology, Allergy, and Immunology, Department of Internal Medicine, College of Medicine, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University, Kaohsiung 833, Taiwan.

Published: February 2024

Long-term Glucocorticoid (GC) use results in compromised bone strength and fractures, and several treatment recommendations have been developed to prevent fractures, but none have been validated in a real-world setting. This study aims to create a treatment decision tool and compares this tool to the treatment suggestions from the American College of Rheumatology (ACR), International Osteoporosis Foundation and European Calcified Tissue Society (IOF-ECTS), and GC-adjusted Fracture Risk Assessment Tool (GC-FRAX), above the intervention threshold. We utilized registry data gathered at Chang Gung Memorial Hospital at Kaohsiung, Taiwan, between September 2014 and April 2021. This research is a single-center, observational, and case-controlled study. We recruited participants using prednisone for at least 2.5 mg/day or the equivalent dose for over 3 months, excluding those younger than 40, those with malignancies, or those currently undergoing anti-osteoporosis therapy. The primary endpoint was new fragility fractures within 3 years, including morphometric vertebral fractures detected at baseline and with a follow-up thoracic-lumbar spine X-ray. Participants were randomly allocated into derivation and validation sets. We developed the Steroid-Associated Fracture Evaluation (SAFE) tool in the derivation cohort by assessing the weights of exploratory variables via logistic regression. Prediction performance was compared in the validation set by the receiver operating characteristic (ROC) curve, the area under the curve (AUC), and sensitivity and specificity. A total of 424 treatment-naïve subjects were enrolled, and 83 (19.6%) experienced new fractures within 3 years. The final formula of the SAFE tool includes osteoporosis (1 point), an accumulated GC dose ≥ 750 mg within 6 months (or equivalent prednisolone of ≥4.5 mg/day for 6 months) (1 point), a BMI ≥ 23.5 (1 point), previous fractures (1 point), and elderliness of ≥70 years (2 points). In the validation set, a treatment decision based on the SAFE ≥ 2 points demonstrated an AUC of 0.65, with a sensitivity/specificity/accuracy of 75.9/54.0/58.9, with an ACR of 0.56 (100.0/11.0/31.0), IOF-ECTS 0.61 (75.9/46.0/52.7), and GC-FRAX 0.62 (82.8/42.0/51.2). Among current GIOP recommendations, the SAFE score serves as an appropriate treatment decision tool with increased accuracy and specificity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10887529PMC
http://dx.doi.org/10.3390/diagnostics14040452DOI Listing

Publication Analysis

Top Keywords

treatment decision
16
decision tool
8
fractures years
8
safe tool
8
validation set
8
treatment
6
fractures
6
tool
6
development comparison
4
comparison treatment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!