A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of reducing sugars in foodstuff applying multivariate second-order calibration. | LitMetric

Determination of reducing sugars in foodstuff applying multivariate second-order calibration.

Anal Methods

Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Suipacha 531, Rosario S2002LRK, Argentina.

Published: June 2016

In the present report, a chemometrics-assisted second-order kinetic-spectrophotometric method has been developed for determining reducing sugars, glucose, fructose and lactose, in food samples, based on the reaction with hexacyanoferrate, HCF, at 70 °C in alkaline medium. A suitable experimental design helped us to establish the conditions (pH, temperature, and HCF concentration) for optimal sensitivity and selectivity among analytes. Second order data were recorded by measuring the absorbance of unreacted HCF in the spectral range of 370 to 470 nm for five minutes using a diode array. A calibration set of samples was prepared according to a central composite design containing the three sugars for training the algorithms. Validation samples containing only the analytes were prepared for checking the reliability of the algorithms. In this particular system, identical profiles for sample components are obtained in the spèctral dimension corresponding to unreacted HCF. Moreover, two kinds of interferents may be present: sample components active in the spectral region at which HCF absorbs as well as potential reducing interferents, causing linear dependence, since they provide identical profiles in spectral dimension to those of the analytes of interest. In the present work, MCR-ALS in the spectral augmentation mode was the only algorithm that could successfully resolve linear dependence. Satisfactory results were obtained by applying MCR-ALS in the spectral augmentation mode in order to achieve a second order advantage for the determination of fructose and glucose in validation samples, in test samples containing the two kinds of interferents and in real food samples, providing LODs of 4.0 and 5.0 mg L, respectively. However, bad results were obtained for lactose which may be due to its low sensitivity in the augmented dimension. Good results were also obtained by applying U-PLS/RBL and N-PLS/RBL for determining simultaneously the three sugars in validation samples and in test samples containing only active spectral interferents. Finally, lactose and also, glucose and fructose, were successfully quantified in real milk samples, with LOD = 1.0 mg L, 1.0 mg L and 0.1 mg L and LOD = 3.5, 3.8 and 4.4 mg L, respectively, using UPLS/RBL, and LOD of 1.3, 1.1 and 0.1 mg L and LOD of 4.0, 4.3 and 4.9 mg L for lactose, glucose and fructose, respectively, for NPLS/RBL. Results for real samples in all cases were statistically comparable to those obtained by applying a reference method based on HPLC (High Performance Liquid Chromatography).

Download full-text PDF

Source
http://dx.doi.org/10.1039/c6ay00964fDOI Listing

Publication Analysis

Top Keywords

glucose fructose
12
validation samples
12
samples
10
reducing sugars
8
food samples
8
second order
8
unreacted hcf
8
three sugars
8
identical profiles
8
sample components
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!