A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anterior cervical discectomy and interbody fusion. An experimental study using a synthetic tricalcium phosphate. | LitMetric

This study evaluates the histological and histochemical changes and osteogenicity of Synthos (tricalcium phosphate ceramic) implanted in the cervical intervertebral space. The cervical vertebrae from C-3 to C-6 were exposed in 20 dogs, and discectomy was performed at the third and fifth spaces. A dowel of Synthos was inserted into the third space, and a piece of fresh autologous graft from the humerus was inserted into the fifth space. The animals were divided into five groups with four animals in each. Four animals were sacrificed at each of 3, 6, 12, 18, and 22 weeks after the procedure. The C-3 to C-6 vertebrae were removed en bloc. One-half of each specimen was processed for histological examination of bone development, while the other half was processed for the two-color fluorescent labeling technique of Suzuki and Matthews for determination of osteogenesis at the time of operation and sacrifice. Various degrees of compression of the Synthos dowel were noted, with anterior and/or posterior displacement of the implant in 70% of the cases. Results indicate that the Synthos implant was biochemically and biomechanically unacceptable for the purposes of this investigation.

Download full-text PDF

Source
http://dx.doi.org/10.3171/jns.1979.51.4.0533DOI Listing

Publication Analysis

Top Keywords

tricalcium phosphate
8
c-3 c-6
8
anterior cervical
4
cervical discectomy
4
discectomy interbody
4
interbody fusion
4
fusion experimental
4
experimental study
4
study synthetic
4
synthetic tricalcium
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!