Intraoperative EEG-based monitors: are we looking under the lamppost?

Curr Opin Anaesthesiol

The Applied Neurophysiology Lab, Rambam Healthcare Campus, Haifa, Israel.

Published: April 2024

Purpose Of Review: While electroencephalogram (EEG)-based depth of anesthesia monitors have been in use clinically for decades, there is still a major debate concerning their efficacy for detecting awareness under anesthesia (AUA). Further utilization of these monitors has also been discussed vividly, for example, reduction of postoperative delirium (POD).It seems that with regard to reducing AUA and POD, these monitors might be applicable, under specific anesthetic protocols. But in other settings, such monitoring might be less contributive and may have a 'built-it glass ceiling'.Recent advances in other venues of electrophysiological monitoring might have a strong theoretical rationale, and early supporting results, to offer a breakthrough out of this metaphorical glass ceiling. The purpose of this review is to present this possibility.

Recent Findings: Following previous findings, it might be concluded that for some anesthesia protocols, the prevailing depth of anesthesia monitors may prevent incidences of AUA and POD. However, in other settings, which may involve other anesthesia protocols, or specifically for POD - other perioperative causes, they may not. Attention-related processes measured by easy-to-use real-time electrophysiological markers are becoming feasible, also under anesthesia, and might be applicable for more comprehensive prevention of AUA, POD and possibly other perioperative complications.

Summary: Attention-related monitoring might have a strong theoretical basis for the prevention of AUA, POD, and potentially other distressing postoperative outcomes, such as stroke and postoperative neurocognitive disorder. There seems to be already some initial supporting evidence in this regard.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ACO.0000000000001339DOI Listing

Publication Analysis

Top Keywords

aua pod
16
purpose review
8
depth anesthesia
8
anesthesia monitors
8
monitoring strong
8
strong theoretical
8
anesthesia protocols
8
pod perioperative
8
prevention aua
8
anesthesia
6

Similar Publications

Intraoperative EEG-based monitors: are we looking under the lamppost?

Curr Opin Anaesthesiol

April 2024

The Applied Neurophysiology Lab, Rambam Healthcare Campus, Haifa, Israel.

Purpose Of Review: While electroencephalogram (EEG)-based depth of anesthesia monitors have been in use clinically for decades, there is still a major debate concerning their efficacy for detecting awareness under anesthesia (AUA). Further utilization of these monitors has also been discussed vividly, for example, reduction of postoperative delirium (POD).It seems that with regard to reducing AUA and POD, these monitors might be applicable, under specific anesthetic protocols.

View Article and Find Full Text PDF

A new base catalyst was derived from submerged fermented pod husk (TCPH) in this work, the developed catalyst was tested for the production of fatty acid ethyl ester (FAEE) using the blends of beef tallow (BTO) - waste use oil (WUO) in the ratios of 10:90 (BTO) 20:80 (BTO) 30:70 (BTO)….., 90:10 (BTO) respectively.

View Article and Find Full Text PDF

Background: Prior studies have demonstrated declines in androgen levels in men with cancer and patients undergoing anesthesia and surgery. In this study, we hypothesized that decreased serum androgen levels are prevalent in male patients undergoing radical cystectomy (RC) for bladder cancer and that it persists in the postoperative period. We characterized perioperative androgen hormonal profiles and examined for associated changes indicative of sarcopenia on computed tomography scans in men undergoing RC.

View Article and Find Full Text PDF

Increased mixing ratios of ground-level ozone (O) threaten individual plants, plant communities and ecosystems. In this sense, O biomonitoring is of great interest. The O-sensitive S156 and the O-tolerant R123 genotypes of snap bean (Phaseolus vulgaris L.

View Article and Find Full Text PDF

We have compared the pharmacokinetics and pharmacodynamics of cyclosporine between once- and twice-daily dosing regimens in de novo patients of living-donor liver transplantation (LDLT). A total of 14 patients were enrolled in this study, who had received cyclosporine microemulsion (Neoral) twice a day (BID, n = 5) or once daily in the morning (QD, n = 9) after transplantation. On postoperative day (POD) 6, the QD regimen significantly increased cyclosporine exposure; the blood concentration at 2 hours postdose (C2) and area under the concentration-time curve (AUC) for 4 hours (AUC(0-4)), compared with the BID regimen.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!