Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A topical medical device, AI500, constituted of a single-chain polypeptide embedded in hyaluronic acid, was tested and evaluated in patients with reduced knee function due to osteoarthritis and other knee conditions. A total of 35 participants with reduced knee function assessed by the WOMAC Physical Function score were recruited. Four study visits were planned, from the first application at V0 to 1 week follow up at V3. Patient symptomatology was evaluated after 24 h (V1) and after 48 h (V2) through phone contact, and after 1 week from V0, on site (V3). The overall duration of the follow up was one week. An amelioration of 40% in WOMAC Physical Functional scores after 1 week of treatment was recorded, thus achieving the primary endpoint of 20%. Furthermore, a reduction of 29% in Physical Functional scores and of 28% in total WOMAC scores between V0-V2 was registered, together with a decrease of 39% between V0 and V3. The NRS scale showed a 29% and 37% reduction in pain between V0-V1 and V0-V2, respectively. Product safety was confirmed by the very low rate of adverse effects, non-device related, observed in only 2 patients out of 35, resolved spontaneously within 24-48 h. No safety concerns or risks associated with the use of the device were highlighted. There are few the studies on the topical use of HA-based gels for the treatment of knee problems. Compared to invasive intra-articular injections and oral pharmacological therapies used in cases of knee pain, the topical application of AI500 is non-invasive, safe, and appreciated by patients. Good results in terms of functional improvement and symptoms resolution were obtained in less than 1 week.