A scoping review of endoscopic and robotic techniques for lateral neck dissection in thyroid cancer.

Front Oncol

Department of Surgery, University of California, Davis Medical Center, Sacramento, CA, United States.

Published: February 2024

Introduction: Lateral neck dissection (LND) in thyroid cancer has traditionally been performed by a transcervical technique with a large collar incision. With the rise of endoscopic, video-assisted, and robotic techniques for thyroidectomy, minimally invasive LND is now being performed more frequently, with better cosmetic outcomes.

Methods: The purpose of this paper is to review the different minimally invasive and remote access techniques for LND in thyroid cancer. A comprehensive literature review was performed using PubMed and Google Scholar search terms "thyroid cancer" and "lateral neck dissection" and "endoscopy OR robot OR endoscopic OR video-assisted".

Results: There are multiple surgical options now available within each subset of endoscopic, video-assisted, and robotic LND. The approach dictates the extent of the LND but almost all techniques access levels II-IV, with variability on levels I and V. This review provides an overview of the indications, contraindications, surgical and oncologic outcomes for each technique.

Discussion: Though data remains limited, endoscopic and robotic techniques for LND are safe, with improved cosmetic results and comparable oncologic and surgical outcomes. Similar to patient selection in minimally invasive thyroidectomy, it is important to consider the extent of the LND and select appropriate surgical candidates.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10883677PMC
http://dx.doi.org/10.3389/fonc.2024.1297972DOI Listing

Publication Analysis

Top Keywords

robotic techniques
12
thyroid cancer
12
minimally invasive
12
endoscopic robotic
8
lateral neck
8
neck dissection
8
lnd thyroid
8
endoscopic video-assisted
8
video-assisted robotic
8
techniques lnd
8

Similar Publications

New Productive Force: The Preliminary Report of First Craniofacial Surgical Robot IST Multicenter Clinical Trial in China.

J Craniofac Surg

January 2025

Department of Plastic and Reconstructive Surgery, Shanghai 9th People's Hospital, School of Medicine, Shanghai Jiao Tong University.

Background: This paper presents the authors' team's research on a craniofacial surgical robot developed in China. Initiated in 2011 with government funding, the craniofacial surgical robot project was officially launched in Shanghai, developed jointly by the Ninth People's Hospital affiliated with Shanghai Jiao Tong University School of Medicine and the Shanghai Jiao Tong University medical-engineering team. Currently, based on multiple rounds of model surgeries, animal experiments, and clinical trials, our team is applying for approval as a Class III medical device from the National Medical Products Administration (NMPA).

View Article and Find Full Text PDF

The high degree of freedom (DoF) shape morphing widely exists in biology for mimicry, camouflage, and locomotion. Currently, a lot of bionic soft/flexible actuators and robots with shape-morphing functions have been developed to realize conformity, grasp, and movement. Among these solutions, two-dimensional responsive materials and structures that can shape morph into different three-dimensional configurations are valuable for creating reversible high DoF shape morphing.

View Article and Find Full Text PDF

Purpose: The double-flap technique (DFT) is an anti-reflux reconstruction procedure performed after proximal gastrectomy (PG), but its complexity and high incidence of anastomotic stenosis are problematic. We conducted this study to demonstrate the efficacy of robot-assisted DFT, with refinements, to address these issues.

Methods: Surgical outcomes were compared between the following procedures modified over time at our institution: conventional open DFT (group O, n = 16); early robotic DFT (group RE, n = 19), which follows the conventional open PG approach; and late robotic DFT (group RL, n = 21), which incorporates refinements to the early robotic DFT technique by exploiting more of the robotic capabilities available.

View Article and Find Full Text PDF

This study applied cumulative sum (CUSUM) analysis to evaluate trends in operative time and blood loss, It aims to identify key milestones in mastering extraperitoneal single-site robotic-assisted radical prostatectomy (ss-RARP). A cohort of 100 patients who underwent ss-RARP, performed by a single surgeon at the First Affiliated Hospital of Guangzhou Medical University between March 2021 and June 2023, was retrospectively analyzed. To evaluate the learning curve, the CUSUM (Cumulative Sum Control Chart) technique was applied, revealing the progression and variability over time.

View Article and Find Full Text PDF

Stereotactic radiosurgery (SRS) and radiotherapy (SRT) have gained prominence as both adjuvant and primary treatment options for patients with skull base tumors that are either inoperable or present as residual or recurrent lesions post-surgery. The object of the current study is to evaluate the safety and efficacy of robotic-assisted SRS and SRT across various skull base pathologies. The study was conducted under PRISMA guidelines and involved a comprehensive evaluation of databases, including PubMed, Scopus, Embase, Web-of-Science, and the Cochrane Library.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!