AI Article Synopsis

  • Fine particulate matter (PM) pollution is linked to cardiovascular issues, potentially through increased inflammation, indicated by higher levels of biomarkers like CRP, IL-6, and TNFα.
  • Portable air cleaners (PACs) effectively reduce PM exposure, with a systematic review of 14 trials showing an average PM reduction of 61.5% and a 7% reduction in CRP and a 13% reduction in IL-6 levels.
  • While active PAC use showed promising results for lowering certain inflammatory biomarkers, no significant effect on TNFα was found, highlighting the need for further research on clinical outcomes.

Article Abstract

Fine particulate matter air pollution (PM) is a major contributor to cardiovascular morbidity and mortality, potentially via increased inflammation. PM exposure increases inflammatory biomarkers linked to cardiovascular disease, including CRP, IL-6 and TNFα. Portable air cleaners (PACs) reduce individual PM exposure but evidence is limited regarding whether PACs also reduce inflammatory biomarkers. We performed a systematic review and meta-analysis of trials evaluating the use of PACs to reduce PM exposure and inflammatory biomarker concentrations. We identified English-language articles of randomized sham-controlled trials evaluating high efficiency particulate air filters in non-smoking, residential settings measuring serum CRP, IL-6 and TNFα before and after active versus sham filtration, and performed meta-analysis on the extracted modeled percent change in biomarker concentration across studies. Of 487 articles identified, we analyzed 14 studies enrolling 778 participants that met inclusion criteria. These studies showed PACs reduced PM by 61.5 % on average. Of the 14 included studies, 10 reported CRP concentrations in 570 participants; these showed active PAC use was associated with 7 % lower CRP (95 % CI: -14 % to 0.0 %, = 0.05). Nine studies of IL-6, with 379 participants, showed active PAC use was associated with 13 % lower IL-6 (95 % CI: [-23 %, -3 %], = 0.009). Six studies, with 269 participants, reported TNF-α and demonstrated no statistical evidence of difference between active and sham PAC use. Portable air cleaners that reduce PM exposure can decrease concentrations of inflammatory biomarkers associated with cardiovascular disease. Additional studies are needed to evaluate clinical outcomes and other biomarkers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10883590PMC
http://dx.doi.org/10.1016/j.ahjo.2022.100182DOI Listing

Publication Analysis

Top Keywords

portable air
12
inflammatory biomarkers
12
pacs reduce
12
systematic review
8
review meta-analysis
8
cardiovascular disease
8
crp il-6
8
il-6 tnfα
8
air cleaners
8
trials evaluating
8

Similar Publications

A portable gas chromatograph-mass spectrometer (GC-MS) is an effective instrument for rapid on-site detection of volatile organic compounds (VOCs). Current instruments typically adsorb samples at ambient temperature, challenging the detection of low-boiling VOCs. In this study, a low-temperature adsorption thermal desorption method is proposed for sample enrichment in a portable GC-MS.

View Article and Find Full Text PDF

Climate change is one of the most crucial issues in human society such that if it is not given sufficient attention, it can become a great threat to both humans and the Earth. Due to global warming, soil erosion is increasing in different regions. Therefore, this issue will require further investigation and the use of new tools.

View Article and Find Full Text PDF

Respiratory interventions including noninvasive ventilation, continuous positive airway pressure and high-flow nasal oxygen generated infectious aerosols may increase risk of airborne disease (SARS-CoV-2, influenza virus) transmission to healthcare workers. We developed and tested a prototype portable UV-C device to sterilize high flows of viral-contaminated air from a simulated patient source at airflow rates of up to 100 l/m. Our device consisted of a central quartz tube surrounded 6 high-output UV-C lamps, within a larger cylinder allowing recirculation past the UV-C lamps a second time before exiting the device.

View Article and Find Full Text PDF

Perioperative hypothermia is a frequent clinical complication resulting from the cold environment of the operating room and prolonged skin exposure, leading to adverse outcomes and increased healthcare burdens. To address this issue, this narrative review discusses in detail the currently common warming strategies for perioperative hypothermia .Forced air warming (FAW) systems are widely recognized as the most effective intervention for maintaining core body temperature.

View Article and Find Full Text PDF

Flexible and Stable GaN Piezoelectric Sensor for Motion Monitoring and Fall Warning.

Nanomaterials (Basel)

December 2024

Center On Nanoenergy Research, Guangxi Key Laboratory for Relativistic Astrophysics, School of Physical Science and Technology, Guangxi University, Nanning 530004, China.

Wearable devices have potential applications in health monitoring and personalized healthcare due to their portability, conformability, and excellent mechanical flexibility. However, their performance is often limited by instability in acidic or basic environments. In this study, a flexible sensor with excellent stability based on a GaN nanoplate was developed through a simple and controllable fabrication process, where the linearity and stability remained at almost 99% of the original performance for 40 days in an air atmosphere.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!