A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel optical dual sensor based on a coaxial electrospinning method for simultaneous sensing of oxygen and ammonia. | LitMetric

A novel optical dual sensor based on a coaxial electrospinning method for simultaneous sensing of oxygen and ammonia.

Heliyon

International Ph.D. Program in Innovative Technology of Biomedical Engineering and Medical Devices, Ming Chi University of Technology, Taishan Dist., New Taipei City, 24301, Taiwan.

Published: February 2024

The coaxial electrospinning method is widely used in a wide range of applications, including medical devices and sensing technology. This study proposes a novel optical dual sensor for simultaneous detection of oxygen (O) and ammonia (NH) based on coaxial electrospinning method to produce core-shell fiber membrane doped fluorescent dyes. The O (core) and NH (shell) sensitive dye membranes were successfully fabricated using coaxial electrospinning method by dissolving a polymer matrix, cellulose acetate (CA), with platinum (II) meso-tetrakis (pentafluorophenyl) porphyrin (PtTFPP) and Eosin-Y, respectively. The optical dual sensor was illuminated by an UV LED to monitor the intensity change and wavelength shift in the presence of selected analyte gases. The experimental data show that the sensitivities of optical dual sensor were found to be 6.4 and 3.2 for O and NH, respectively. The response and recovery times of O and NH sensing probes were measured to be 12 s/29 s and 65 s/66 s, respectively. Also, when exposed to NH gas gradually from 0 to 500 ppm, the wavelength shift data of Eosin-Y was started at 569.5 nm, 573.9 nm, 578.4 nm, 579.4 nm, 580.8 nm, and 582.2 nm, respectively. In applications, the proposed optical dual sensor based on coaxial electrospinning method can detect O and NH gases simultaneously.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10881840PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e25983DOI Listing

Publication Analysis

Top Keywords

optical dual
20
dual sensor
20
coaxial electrospinning
20
electrospinning method
20
based coaxial
12
novel optical
8
sensor based
8
oxygen ammonia
8
wavelength shift
8
dual
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!