Background: It is clinically needed to explore a more efficient imaging protocol for single photon emission computed tomography (SPECT) myocardial blood flow (MBF) quantitation derived from cadmium zinc telluride (CZT) SPECT camera for the routine clinical utilization.

Methods: One hundred and twenty patients with matched clinical characteristics and angiographic findings who completed one-day rest/stress SPECT imaging with either the intermittently sequential imaging (ISI) protocol (two dynamic and two electrocardiography (ECG)-gated scans) or the continuous rapid imaging (CRI) protocol (two dynamic/ECG-gated scans) were included. MBF quantitation adopted residual activity correction (RAC) to correct for rest residual activity (RRA) in the stress dynamic SPECT scan for the detection of flow-limited coronary artery disease.

Results: The CRI protocol reduced about 6.2 times shorter than the ISI protocol (25.5 min vs 157.6 min), but slightly higher than the RRA (26.7% ± 3.6% vs 22.3% ± 4.9%). With RAC, both protocols demonstrated close stress MBF (2.18 ± 1.13 vs 2.05 ± 1.10, P > 0.05) and myocardial flow reserve (MFR) (2.42 ± 1.05 vs 2.48 ± 1.11, P > 0.05) to deliver comparable diagnostic performance (sensitivity = 82.1%-92.3%, specificity = 81.2%-91.2%). Myocardial perfusion and left ventricular function overall showed no significant difference (all P > 0.26).

Conclusion: One-day rest/stress SPECT with the CRI protocol and rest RAC is feasible to warrant the diagnostic performance of MBF quantitation with a shortened examination time and enhanced patient comfort. Further evaluation on the impact of extracardiac activity to regional MBF and perfusion pattern is required. Additional evaluation is needed in a patient population that is typical of those referred for SPECT MPI, including those with known or suspected coronary microvascular disease.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.nuclcard.2024.101825DOI Listing

Publication Analysis

Top Keywords

one-day rest/stress
12
mbf quantitation
12
cri protocol
12
myocardial blood
8
blood flow
8
flow-limited coronary
8
coronary artery
8
continuous rapid
8
rapid imaging
8
imaging protocol
8

Similar Publications

Comparative evaluation of a novel [F] F-Labeled PET tracer XTR004 against [N] ammonia in myocardial perfusion imaging for coronary artery disease.

Eur J Nucl Med Mol Imaging

December 2024

Department of Nuclear Medicine, Peking Union Medical College Hospital. Chinese Academy of Medical Science & Peking Union Medical College, Beijing Key Laboratory of Molecular Targeted Diagnosis and Therapy in Nuclear Medicine, Shuaifuyuan, Dongcheng District, Beijing, 100730, China.

Aims: This study aimed to evaluate image quality, myocardial perfusion, and diagnostic performance of a novel [F]F-labeled PET tracer, XTR004 PET, myocardial perfusion imaging (MPI) compared with [N]Ammonia (NH) PET MPI.

Methods And Results: Forty-seven patients with suspected or known coronary artery disease (CAD) were prospectively enrolled to undergo one-day rest/ATP-stress XTR004 and NH electrocardiograph-gated PET imaging within 2 weeks. Among them, twenty-six patients underwent invasive coronary angiography (ICA), and nineteen were identified with flow-limited CAD (stenosis ≥ 70%).

View Article and Find Full Text PDF

Objective: Transient ischaemic dilatation (TID) had incremental diagnostic and prognostic value in obstructive coronary artery disease (CAD), but its clinical significance in patients with non-obstructive CAD remains unknown. We aimed to explore the prognostic value of TID in patients with non-obstructive CAD by N-ammonia PET imaging.

Methods: We retrospectively studied 131 consecutive patients with non-obstructive CAD undergoing one-day rest-stress N-ammonia PET myocardial perfusion imaging (MPI).

View Article and Find Full Text PDF

Background: It is clinically needed to explore a more efficient imaging protocol for single photon emission computed tomography (SPECT) myocardial blood flow (MBF) quantitation derived from cadmium zinc telluride (CZT) SPECT camera for the routine clinical utilization.

Methods: One hundred and twenty patients with matched clinical characteristics and angiographic findings who completed one-day rest/stress SPECT imaging with either the intermittently sequential imaging (ISI) protocol (two dynamic and two electrocardiography (ECG)-gated scans) or the continuous rapid imaging (CRI) protocol (two dynamic/ECG-gated scans) were included. MBF quantitation adopted residual activity correction (RAC) to correct for rest residual activity (RRA) in the stress dynamic SPECT scan for the detection of flow-limited coronary artery disease.

View Article and Find Full Text PDF

N-ammonia positron emission tomography (NH-PET) can evaluate myocardial blood flow (MBF) at rest, stress, and myocardial flow reserve (MFR) as well as the ratio of MBF at stress to that at rest. MFR is useful in predicting the prognoses of patients with various heart diseases. Cadmium-zinc-telluride single photon emission computed tomography (CZT-SPECT) enables us to acquire dynamic images of radiotracer kinetics and measure original MBF and MFR using Tc-sestamibi.

View Article and Find Full Text PDF

Background: Measurement of myocardial blood flow (MBF) is feasible using SPECT imaging but the acquisition requires more time than usual. Our study assessed the impact of reducing acquisition times on the accuracy and repeatability of the uptake rate constant (K1).

Methods: Twenty-nine patients underwent two rest/stress studies with Tc-99m-tetrofosmin 18 ± 13 days apart, using a one-day rest/stress dynamic SPECT imaging protocol with a solid-state cardiac camera.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!