The treatment of critical-sized bone defects has long been a major problem for surgeons. In this study, an intramedullary nail shaped three-dimensional (3D)-printed porous titanium implant that is capable of releasing strontium ions was developed through a simple and cost-effective surface modification technique. The feasibility of this implant as a stand-alone solution was evaluated using a rabbit's segmental diaphyseal as a defect model. The strontium-loaded implant exhibited a favorable environment for cell adhesion, and mechanical properties that were commensurate with those of a rabbit's cortical bone. Radiographic, biomechanical, and histological analyses revealed a significantly higher amount of bone ingrowth and superior bone-bonding strength in the strontium-loaded implant when compared to an untreated porous titanium implant. Furthermore, one-year histological observations revealed that the strontium-loaded implant preserved the native-like diaphyseal bone structure without failure. These findings suggest that strontium-releasing 3D-printed titanium implants have the clinical potential to induce the early and efficient repair of critical-sized, load-bearing bone defects.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.35393DOI Listing

Publication Analysis

Top Keywords

titanium implant
12
strontium-loaded implant
12
intramedullary nail
8
bone defects
8
porous titanium
8
implant
7
bone
5
strontium-loaded
4
strontium-loaded intramedullary
4
titanium
4

Similar Publications

Intracranial Hypotension Mechanism and Implant Retention Procedure for Patients With Titanium Mesh Exposure.

Oper Neurosurg (Hagerstown)

January 2025

Department of Neurosurgery, Huashan Hospital, Shanghai Medical College, Fudan University, Shanghai, China.

Background And Objectives: The study aimed to investigate the potential pathogenesis and present an implant retention procedure for patients with titanium mesh exposure after cranioplasty.

Methods: The clinical data were obtained from 26 consecutive cases with titanium mesh exposure who underwent surgical treatment between 2018 and 2023. These patients' medical records, scalp photographs, operative notes, and outcomes were retrospectively analyzed.

View Article and Find Full Text PDF

Recent focus has shifted toward refining the soft tissue emergence profile to enhance aesthetics, support peri-implant health, and ensure long-term success. Traditionally, titanium stock healing abutments or chairside-customized abutments were used to shape peri-implant tissues and develop the emergence profile for implant-supported prostheses. However, advancements in digital dentistry now allow for more precise customization and increased treatment efficiency.

View Article and Find Full Text PDF

Construction and high-throughput screening of gradient nanowire coatings on titanium surface towards ameliorated osseointegration.

Mater Today Bio

February 2025

Shanxi Key Laboratory of Biomedical Metal Materials, College of Materials Science and Engineering, Taiyuan University of Technology, Taiyuan, 030024, China.

Surface nano-modification has emerged as an effective strategy to enhance osseointegration of titanium (Ti) implants. Despite its promise, rational optimization of surface nanomorphology for ameliorated osseointegration remains a significant challenge. Our research pioneering developed a one-step alkali etching technique to produce a gradient nanowire coating with continuously varied dimensions on Ti surfaces, which was subsequently served as a versatile platform for high-throughput screening of optimal dimensions to enhance osseointegration.

View Article and Find Full Text PDF

Molding Quality and Biological Evaluation of a Two-Stage Titanium Alloy Dental Implant Based on Combined 3D Printing and Subtracting Manufacturing.

ACS Omega

December 2024

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration & National Clinical Research Center for Oral Diseases & Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi'an 710032, Shaanxi, P. R. China.

Metal 3D printing has been used in the manufacturing of dental implants. Its technical advantages include high material utilization and the capacity to form arbitrarily complex structures. However, 3D printing alone is insufficient for manufacturing two-stage titanium implants due to the limited precision in printing titanium alloy parts.

View Article and Find Full Text PDF
Article Synopsis
  • The study explores the antibacterial effects of tantalum-copper (Ta-Cu) coatings on titanium alloys to combat infections from orthopedic and dental implants.
  • The coatings were created with different copper percentages and subjected to various thermal treatments, with the TaCu-2 sample (∼10 wt% copper, annealed at 600 °C) showing the best antibacterial performance.
  • Optimizing the copper content and annealing temperature was found to be crucial in improving the antibacterial properties of these coatings, suggesting their potential for reducing implant-related infections.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!