Background: The impact of pronation and sesamoid coverage on clinical outcomes following percutaneous hallux valgus surgery are not currently known. The aim of this study was to investigate if sesamoid coverage was associated with worse clinical outcomes at 12-month follow-up following percutaneous hallux valgus surgery.

Methods: Retrospective comparative observational study of clinical and radiographic outcomes based on a previously published prospective dataset. Patients were stratified into 3 cohorts based on the degree of sesamoid coverage (normal, mild, or moderate) on 12-month weightbearing radiographs following fourth-generation percutaneous hallux valgus surgery. Primary outcome was a validated patient-reported outcome measure (PROM), the Manchester-Oxford Foot Questionnaire (MOXFQ). Secondary outcomes included Euroqol-5D, VAS Pain, and radiographic deformity correction.

Results: Forty-seven feet underwent primary fourth-generation HV surgery and were stratified into 3 cohorts. There were 19, 16, and 12 feet in the normal, mild, and moderate cohorts respectively. There was no significant difference in either pre- or postoperative foot function (all MOXFQ domains,  > .05) or health-related quality of life (EQ-5D Index or VAS,  > .05). The MOXFQ Index preoperatively was as follows: normal cohort, 56.1 ± 26.9; mild cohort, 54.1 ± 17.9; and severe cohort, 49.6 ± 23.8; and postoperatively was as follows: normal cohort, 15.6 ± 21.5; mild cohort, 11.4 ± 15.5; and severe cohort, 11.4 ± 13.6 ( = .737-.908). There was significantly worse hallux valgus angle (HVA) and intermetatarsal angle (IMA) between the cohorts ( < .01). Although HVA and IMA were corrected to normal parameters following surgery in all cohorts, there was a significantly worse postoperative HVA in the moderate sesamoid coverage (5.3 ± 3.9 vs 7.9 ± 5.3 vs 11.4 ± 3.7,  < .01); however, IMA was not significantly different (3.4 ± 2.2 vs 4.1 ± 2.7 vs 5.2 ± 2.9,  = .168).

Conclusion: This study found that cases where the sesamoids were not reduced had a poorer correction and had worse preoperative deformity. Clinical outcomes and foot function following fourth-generation percutaneous hallux valgus surgery were not affected by sesamoid coverage at the 12-month follow-up. The long-term implications in the difference in radiographic deformity between the 3 cohorts are not known, and further work should explore the relationship of first ray pronation and sesamoid position, particularly with regard to recurrence.

Level Of Evidence: Level III, retrospective comparative study of prospectively collected data.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10880538PMC
http://dx.doi.org/10.1177/24730114241230560DOI Listing

Publication Analysis

Top Keywords

hallux valgus
20
sesamoid coverage
16
percutaneous hallux
16
valgus surgery
12
coverage clinical
8
foot function
8
fourth-generation percutaneous
8
clinical outcomes
8
stratified cohorts
8
normal mild
8

Similar Publications

Navigating the complexities of hallux valgus surgery.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.

View Article and Find Full Text PDF

Background: Scarf osteotomy is a well-established procedure for hallux valgus, yet recurrence rates range from 3.6% to 10%. Pes planus, which often coexisting with hallux valgus, is a risk factor for recurrence.

View Article and Find Full Text PDF

Background: This study aimed to investigate the safety and reliability of using bioabsorbable screws for the fixation of chevron osteotomy in the treatment of hallux valgus (HV) deformity.

Methods: Clinical cases of chevron osteotomy in the treatment of HV deformities in our hospital between December 2018 and August 2022 were retrospectively summarised to compare preoperative imaging indices with those at the final follow-up session, including the hallux valgus angle (HVA), intermetatarsal angle (IMA) and tibial sesamoid position (TSP). The American Orthopaedic Foot and Ankle Society (AOFAS) hallux metatarsophalangeal-interphalangeal scale, short-form health survey questionnaire (SF-36) and European Foot and Ankle Society (EFAS) scale were used to assess therapeutic efficacy.

View Article and Find Full Text PDF

Researchers have modified PLA materials to enhance their mechanical properties and meet the clinical requirements. However, the strength and stiffness of PLA are still significantly lower than those of metals. Building on the established chevron clinical procedure and considering the mechanical characteristics of PLA screws, we devised a modified chevron osteotomy (MCO) based on a load-reducing structure with the aim of reducing the load on the screws.

View Article and Find Full Text PDF

An alternative fixation for all mild and moderate hallux valgus cases enabling intraoperative readjustment.

J Orthop Surg Res

January 2025

Department of Orthopaedics and Traumatology, Adana City Training and Research Hospital, University of Health Sciences, Adana, Turkey.

Background: The development of a cost-effective and easily applicable fixation method to address all components of hallux valgus (HV) surgery is of great importance to the field. This study aims to assess the clinical efficacy of an  alternative fixation method that combines the advantages aspects of commonly used distal osteotomy techniques and evaluate its level of applicability in the treatment of mild and moderate HV cases.

Methods: The retrospectively designed study was conducted at Adana City Training and Research Hospital, Adana, Türkiye.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!