Electrical capacitance tomography (ECT) is a non-optical imaging technique in which a map of the interior permittivity of a volume is estimated by making capacitance measurements at its boundary and solving an inverse problem. While previous ECT demonstrations have often been at centimeter scales, ECT is not limited to macroscopic systems. In this paper, we demonstrate ECT imaging of polymer microspheres and bacterial biofilms using a CMOS microelectrode array, achieving spatial resolution of 10 microns. Additionally, we propose a deep learning architecture and an improved multi-objective training scheme for reconstructing out-of-plane permittivity maps from the sensor measurements. Experimental results show that the proposed approach is able to resolve microscopic 3-D structures, achieving 91.5% prediction accuracy on the microsphere dataset and 82.7% on the biofilm dataset, including an average of 4.6% improvement over baseline computational methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10880799PMC
http://dx.doi.org/10.1109/biocas58349.2023.10388576DOI Listing

Publication Analysis

Top Keywords

capacitance tomography
8
microscale 3-d
4
3-d capacitance
4
tomography cmos
4
cmos sensor
4
sensor array
4
array electrical
4
electrical capacitance
4
ect
4
tomography ect
4

Similar Publications

An electrical characteristics extraction and analysis method for membrane of medaka embryo during its development using Electrical Impedance Spectroscopy (EIS) is proposed. The proposed method is non-invasive, it doesn't affect the embryo's development. Embryo's equivalent electrical circuit (EEC) model is established to extract membrane's electrical characteristics, it is used to fit the embryo's electrical impedance curves in different developmental stages.

View Article and Find Full Text PDF

As the interface between frozen and unfrozen soil, the ice front is not only a spatial location concept, but also a potentially dangerous interface where the mechanical properties of soil could change abruptly. Accurately identifying its spatial position is essential for the safe and efficient execution of large-scale frozen soil engineering projects. Electrical capacitance tomography (ECT) is a promising method for the visualization of frozen soil due to its non-invasive nature, low cast, and rapid response.

View Article and Find Full Text PDF

Continuously monitoring human airway conditions is crucial for timely interventions, especially when airway stents are implanted to alleviate central airway obstruction in lung cancer and other diseases. Mucus conditions, in particular, are important biomarkers for indicating inflammation and stent patency but remain challenging to monitor. Current methods, reliant on computational tomography imaging and bronchoscope inspection, pose risks due to radiation and lack the ability to provide continuous real-time feedback outside of hospitals.

View Article and Find Full Text PDF

Research on capacitance-coupled electrical impedance imaging fusion algorithm based on wavelet transform.

Rev Sci Instrum

October 2024

School of Mechanical and Precision Instrument Engineering, Xi an University of Technology, No. 5 Jinhuanan Road, Xi'an 710048, People's Republic of China.

Capacitively Coupled Electrical Impedance Tomography (CCEIT), as a new electrical tomography method, effectively overcomes the drawbacks of traditional electrical resistance tomography that requires direct contact with liquids, so as to achieve non-contact measurement. In order to make full use of the complete electrical impedance information (real and imaginary) obtained by CCEIT and further improve the quality of image reconstruction, an image fusion algorithm based on wavelet transform was proposed. First, the Landweber algorithm is used to image the real part information and the imaginary part information, and the wavelet transform algorithm is used to decompose the two images at multiple scales, in which the low-frequency coefficient is fused by the improved logic filter algorithm based on the adaptive threshold, the high-frequency coefficient is selected based on the absolute value maximum method for fusion, and finally, the fused image is obtained by wavelet reconstruction.

View Article and Find Full Text PDF

Soft sensors that can perceive multiaxial forces, such as normal and shear, are of interest for dexterous robotic manipulation and monitoring of human performance. Typical planar fabrication techniques have substantial design constraints that often prohibit the creation of functionally compelling and complex architectures. Moreover, they often require multiple-step operations for production.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!