Background: The aim of the present study was to evaluate the long-term safety and effectiveness of the subcutaneous implantable cardioverter defibrillator (S-ICD) when implanted intermuscularly in patients with end-stage renal disease and hemodialysis.
Methods: This study is a retrospective analysis of 21 consecutive patients implanted with S-ICDs at three experienced centers in Germany with comorbid renal insufficiency requiring hemodialysis, as well as being at risk of sudden cardiac death. The S-ICD was placed intermuscularly in all patients. Follow-ups (FUs) were performed every 6 months.
Results: The mean ± standard deviation FU duration was 60.0 ± 11.4 months, with a range of 39 to 78 months. There were no deaths due to arrhythmia, or device-associated infections and complications. Four patients (19.1%) died during FU due to respiratory insufficiency during dialysis, systolic heart failure, septic infection of the urogenital tract, and colorectal cancer, respectively. There were six non-device-related hospitalizations with a duration of 12.7 ± 5.1 days and a hospitalization rate of 4.1 per 100 patient years.
Conclusions: In the long-term FU of this small population of seriously compromised hemodialysis patients at risk of sudden cardiac death, the intermuscularly implanted S-ICD system was safe and effective. No arrhythmic complications, device-associated infections, or complications compromised survival. These data are encouraging and support testing in a larger group of similarly compromised patients.