A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preeclampsia/eclampsia impacts the structure and function of neonatal hearts probably by reducing myocardial compaction. | LitMetric

Purpose: Preeclampsia/Eclampsia (PE/E) poses significant risks to neonatal cardiac health. Traditional echocardiographic methods have limitations in detailing these impacts. This study hypothesized that echocardiographic radiomics could provide a more comprehensive assessment of the cardiac changes in neonates affected by PE/E.

Method: In a comprehensive analysis, 2594 neonates underwent echocardiographic screening. From these, 556 were selected for detailed radiomics analysis, focusing on cardiac shape, movement, and texture features. A multiblock sparse partial least squares (sPLS) model integrated these features to assess their association with PE/E.

Results: Newborns from PE/E-affected pregnancies displayed lower left ventricular ejection fractions compared to the control group (61.1 % vs. 66.2 %). Our radiomics approach extracted 15,494 features per neonate, with the sPLS model identifying 17 features significantly correlated with PE/E. Among these, texture features representing myocardial non-compaction were most strongly correlated with PE/E (correlation coefficient r = 0.63). Detailed visualization of these texture features suggested that PE/E might lead to more pronounced myocardial non-compaction, characterized by a thicker non-compaction layer and increased cardiac trabeculation.

Conclusions: Our findings demonstrate the potential of echocardiographic radiomics as a tool for assessing the impact of PE/E on neonatal cardiac function. The correlation between PE/E and myocardial non-compaction underlines the need for enhanced cardiac monitoring in neonates born to PE/E-affected mothers. This study contributes to a better understanding of PE/E's cardiac implications, potentially guiding future clinical practices.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2024.111382DOI Listing

Publication Analysis

Top Keywords

texture features
12
myocardial non-compaction
12
neonatal cardiac
8
echocardiographic radiomics
8
spls model
8
correlated pe/e
8
cardiac
7
pe/e
6
features
6
preeclampsia/eclampsia impacts
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!