A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the German Version of the Keratoconus Outcomes Research Questionnaire. | LitMetric

AI Article Synopsis

  • The study aimed to translate and validate the German version of the Keratoconus Outcomes Research Questionnaire (KORQ) to ensure it is psychometrically sound.
  • In three phases, the KORQ was translated, tested for reliability through Rasch analysis, and evaluated with a separate patient cohort using corneal imaging techniques.
  • The final shortened version of the German KORQ demonstrated excellent reliability and validity, suggesting it can be a valuable tool for assessing patient outcomes in those with keratoconus.

Article Abstract

Purpose: To translate, validate, and evaluate the psychometric properties of the German version of Keratoconus Outcomes Research Questionnaire (KORQ).

Methods: This prospective study included 3 phases. In phase 1, the KORQ was translated in a standardized way; in phase 2, Rasch validation was performed; in phase 3, the validated questionnaire was evaluated in a separate patient cohort. All patients answered the German KORQ. Scheimpflug imaging (Pentacam) and optical coherence tomography scans (MS-39) were conducted. Corneal imaging measurements were correlated with patient-reported outcome measures.

Results: After standardized translation, 100 patients self-administered the German KORQ. Rasch analysis was conducted for psychometric testing of the KORQ. Based on the results of the Rasch analysis, the original German version of the KORQ was modified and any items showing a misfit were excluded. This resulted in a new shortened version of the KORQ, which was evaluated in 30 patients. The revised German KORQ met the criteria of Rasch analysis and showed excellent internal consistency reliability and convergent validity. The correlation between the KORQ score and various clinical measurements was examined using Spearman correlation. A significant moderate correlation was observed between the D (r = 0.237; P = 0.006) and K max (r = 0.162; P = 0.065) values of Pentacam. Inverse correlations were observed for thinnest pachymetry measured with MS-39 (r = -0.167; P = 0.058) and best corrected visual acuity (r = -0.210; P = 0.016).

Conclusions: The shortened German KORQ met the assumptions of the Rasch model and displayed satisfactory psychometric properties. The German KORQ could be adopted as a powerful patient-reported outcome measures tool for German-speaking patients with keratoconus in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000003506DOI Listing

Publication Analysis

Top Keywords

german korq
20
german version
12
rasch analysis
12
korq
10
version keratoconus
8
keratoconus outcomes
8
outcomes questionnaire
8
psychometric properties
8
properties german
8
patient-reported outcome
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!