Objectives: No consensus regarding the optimal position and location for the measurement of the inter-rectus distance (IRD) via ultrasound (US) has been reached. By investigating the intra- and interimage reliability of IRD measurements taken in different positions and at different locations within and between testers, this study provides a theoretical basis for the current situation.

Methods: The IRD was measured via US in 46 women at 42-60 days after delivery at the superior margin of the umbilicus and 3 cm above, 5 cm above and 3 cm below the umbilicus while the women were in the supine, crunch and standing positions. In the interimage test, every participant was tested 2 times by Physician X and 1 time by Physician Y; in the intraimage test, the images collected by Physician X during the first test were saved in the machines, and two measurements were performed by Physician X and one measurement was performed by Physician Y. Paired t tests and intraclass correlation coefficients (ICCs) were calculated.

Results: Only the first IRD measurements by tester X and tester Y at 3 cm below the umbilicus in the crunch position were significantly different (9.56 ± 6.00 versus 11.00 ± 5.55) (P < .05). All the ICCs were greater than .75, and the intratester ICCs were greater than or equal to the corresponding intertester ICCs. The ICCs at 3 cm below the umbilicus were the smallest in the supine and crunch positions and the largest in the standing position due to the increased frequency of IRD values of 0. The ICCs for the crunch position were greatest according to the intraimage test but smallest according to the interimage test. The interimage ICCs between the two testers in the supine position at the superior margin, 3 cm above, 5 cm above, and 3 cm below the umbilicus were .972, .974, .975, and .956, respectively.

Conclusions: Ultrasound imaging (USI) is a reliable method for measuring the IRD in women in the early postpartum period. The dynamic measurement of the IRD at or above the umbilicus in the supine position by different testers in real time showed the highest reliability.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jum.16430DOI Listing

Publication Analysis

Top Keywords

intra- interimage
8
interimage reliability
8
inter-rectus distance
8
ird measurements
8
3 cm umbilicus
8
performed physician
8
physician
5
reliability inter-rectus
4
measurements
4
distance measurements
4

Similar Publications

Breast lesion segmentation from ultrasound images is essential in computer-aided breast cancer diagnosis. To alleviate the problems of blurry lesion boundaries and irregular morphologies, common practices combine CNN and attention to integrate global and local information. However, previous methods use two independent modules to extract global and local features separately, such feature-wise inflexible integration ignores the semantic gap between them, resulting in representation redundancy/insufficiency and undesirable restrictions in clinic practices.

View Article and Find Full Text PDF

Purpose: This study aims to investigate inter-image intra-observer variability of macular, and optic disc (ONH) microvasculature measurements of glaucomatous and normal subjects using Swept-Source Optical Coherence Tomography Angiography (OCT-A) (OCT Topcon ImageNet 6; DRI OCT Triton, Topcon Corporation, JAPAN) - based imaging data analysis and processing with a newly made quantitative approach.

Methods: A total of 20 glaucomatous and 20 healthy eyes underwent three OCT-A scanning of the ONH and macula. Macular and papillary and peripapillary vascular networks were calculated.

View Article and Find Full Text PDF

Objectives: No consensus regarding the optimal position and location for the measurement of the inter-rectus distance (IRD) via ultrasound (US) has been reached. By investigating the intra- and interimage reliability of IRD measurements taken in different positions and at different locations within and between testers, this study provides a theoretical basis for the current situation.

Methods: The IRD was measured via US in 46 women at 42-60 days after delivery at the superior margin of the umbilicus and 3 cm above, 5 cm above and 3 cm below the umbilicus while the women were in the supine, crunch and standing positions.

View Article and Find Full Text PDF

Aortic segmentation from computed tomography (CT) is crucial for facilitating aortic intervention, as it enables clinicians to visualize aortic anatomy for diagnosis and measurement. However, aortic segmentation faces the challenge of variable geometry in space, as the geometric diversity of different diseases and the geometric transformations that occur between raw and measured images. Existing constraint-based methods can potentially solve the challenge, but they are hindered by two key issues: inaccurate definition of properties and inappropriate topology of transformation in space.

View Article and Find Full Text PDF

Measuring the similarity of two images is of crucial importance in computer vision. Class agnostic common object detection is a nascent research topic about mining image similarity, which aims to detect common object pairs from two images without category information. This task is general and less restrictive which explores the similarity between objects and can further describe the commonality of image pairs at the object level.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!