This paper presents an analytical solution for fluid flow and heat transfer inside arbitrarily-shaped triangular ducts for the first time. The former analytical solutions are limited to the special case of isosceles triangular ducts. The literature has no report about the analytical solution for the general case of arbitrarily-shaped triangular ducts. Due to the significant role of fluid flow through non-circular channels in industry and the large number of triangular shapes, a method for solving the heat transfer problem for all triangular shapes is needed. The heat transfer of a fluid flow through a channel with an arbitrary triangular cross-section for the case of constant heat flux at the walls is solved in this work for the first time, considering viscous dissipation. Here, the functionals of flow and heat transfer equations are derived, and the resulting Euler-Lagrange equations are solved using the Ritz method. The effect of the duct geometry on the velocity profile and friction coefficient is studied in detail. The effect of the Brinkman number on the temperature distribution and Nusselt number is investigated for both cooling and heating cases. The results reveal that the critical Brinkman Number distinguishes between the cooling and heating cases and represents the critical point at which the Nusselt number approaches infinity. The value of the Nusselt number decreases with the increase of the Brinkman number in both the wall cooling and heating modes. It is also found that the equilateral triangle exhibits the minimum friction coefficient and the maximum value of the Poiseuille number.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10877169PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e25293DOI Listing

Publication Analysis

Top Keywords

fluid flow
16
triangular ducts
16
heat transfer
16
analytical solution
12
flow heat
12
brinkman number
12
nusselt number
12
cooling heating
12
solution fluid
8
arbitrarily-shaped triangular
8

Similar Publications

An 8 yr old, male, mixed-breed dog was presented with a 2 mo history of progressive weakness, worsened in the last 2 days before examination. Neurological examination revealed ambulatory tetraparesis, ataxia, and proprioceptive deficits in all four limbs. Menace response was reduced in the right eye and discomfort was detected on neck manipulation.

View Article and Find Full Text PDF

The physiological and clinical importance of motile cilia in reproduction is well recognized, however, the specific role they play in transport through the oviduct and how ciliopathies lead to subfertility and infertility is still unclear. The contribution of cilia beating, fluid flow, and smooth muscle contraction to overall progressive transport within the oviduct remains under debate. Therefore, we investigated the role of cilia in the oviduct transport of preimplantation eggs and embryos using a combination of genetic and advanced imaging approaches.

View Article and Find Full Text PDF

Recent studies have reported that monitoring spinal cord perfusion pressure (SCPP) using a pressure probe to measure "intraspinal pressure" (ISP) within the subdural space at the injury site may improve the hemodynamic management of acute spinal cord injury (SCI) patients. This study aimed to investigate, within a pig model of SCI, the relationship between the ISP measured within the subdural space and the "spinal cord pressure" (SCP) measured within the spinal cord itself. Specifically, we sought to characterize the changes to ISP and SCP over time, both rostral and caudal to the injury epicenter, and in relation to native spinal cord morphometry.

View Article and Find Full Text PDF

Intravenous Pump Flow Accuracy: A Systematic Review.

J Infus Nurs

December 2024

Author Affiliations: Elaine Marieb College of Nursing, Elaine Marieb Center for Nursing & Engineering Innovation, University of Massachusetts Amherst, Amherst, Massachusetts.

Intravenous pumps (IVPs) deliver IV medications to millions of acute care patients each year and result in many adverse events reported to the US Food and Drug Administration (FDA). Although the use of IVPs has improved overall safety, there are still high rates of error that risk the safety of all patients, especially those of advanced age and those suffering from critical illness. Most of the documented errors are based on clinician reports, although there is reason to believe that errors due to flow rate inaccuracy go undetected and unreported.

View Article and Find Full Text PDF

Predicting the evolution of ascending aortic aneurysm (AscAA) growth is a challenge, complicated by the intricate interplay of aortic geometry, tissue behavior, and blood flow dynamics. We investigate a flow-structural growth and remodeling (FSG) model based on the homogenized constrained mixture theory to simulate realistic AscAA growth evolution. Our approach involves initiating a finite element model with an initial elastin insult, driven by the distribution of Time-Averaged Wall Shear Stress (TAWSS) derived from computational fluid dynamics simulations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!