Introductions: Cystic fibrosis-related diabetes (CFRD) is associated with pulmonary decline, compromised nutritional status, and earlier mortality. Onset is often insidious, so screening for early detection of glycemic abnormalities is important. Continuous glucose monitoring (CGM) has been validated in people with CF and has been shown to detect early glycemic variability otherwise missed on 2-hour oral glucose tolerance testing (OGTT). We previously reported that CGM measures of hyperglycemia and glycemic variability are superior to hemoglobin A1c (HbA1c) in distinguishing those with and without CFRD. However, little is known about the long-term predictive value of CGM measures of glycemia for both the development of CFRD and their effect on key clinical outcomes such as weight maintenance and pulmonary function. In addition, there have been no studies investigating advanced glycation endproducts (AGE) assessed by skin autofluorescence in people with CF.

Methods: In this prospective observational study, CGM and HbA1c were measured at 2 to 3 time points 3 months apart in 77 adults with CF. Participants who did not have CFRD at the time of enrollment underwent OGTT at the baseline visit, and all participants had AGE readings at baseline. Follow up data including anthropometric measures, pulmonary function and CFRD status were collected by review of medical records 1- and 2-years after the baseline visits. We applied multivariable linear regression models correlating glycemic measures to change in key clinical outcomes (weight, BMI, FEV1) accounting for age, gender and elexacaftor/tezacaftor/ivacaftor (ETI) use. We also conducted logistic regression analyses comparing baseline glycemic data to development of CFRD during the 2-year follow up period.

Results: Of the 77 participants, 25 had pre-existing CFRD at the time of enrollment, and six participants were diagnosed with CFRD by the OGTT performed at the baseline visit. When adjusting for age, gender, and ETI use, multiple CGM measures correlated with weight and BMI decline after one year but not after two years. CGM and HbA1c at baseline did not predict decline in FEV1 (p>0.05 for all). In the 46 participants without a diagnosis of CFRD at baseline, two participants were diagnosed with CFRD over the following two years, but CGM measures at baseline did not predict progression to CFRD. Baseline AGE values were higher in individuals with CFRD and correlated with multiple measures of dysglycemia (HbA1c, AG, SD, CV, TIR, % time >140, >180, >250) as well as weight. AGE values also correlated with FEV1 decline at year 1 and weight decline at year 1 and year 2.

Conclusions: Several key CGM measures of hyperglycemia and glycemic variability were predictive of future decline in weight and BMI over one year in this population of adults with CF with and without CFRD. None of the baseline glycemic variables predicted progression to CFRD over 2 years. To our knowledge, this is the first report correlating AGE levels with key clinical and glycemic measures in CF. Limitations of these analyses include the small number of participants who developed CFRD (n=2) during the follow up period and the initiation of ETI by many participants, affecting their trajectory in weight and pulmonary function. These results provide additional data supporting the potential role for CGM in identifying clinically significant dysglycemia in CF. Future studies are needed to investigate CGM as a diagnostic and screening tool for CFRD and to understand the implications of AGE measures in this patient population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10876871PMC
http://dx.doi.org/10.3389/fendo.2024.1293709DOI Listing

Publication Analysis

Top Keywords

cgm measures
20
cfrd
16
clinical outcomes
12
glycemic variability
12
key clinical
12
pulmonary function
12
weight bmi
12
decline year
12
cfrd baseline
12
cgm
10

Similar Publications

Objective: Post-prandial glucose response (PPGR) is a risk factor for cardiovascular disease. Meal carbohydrate content is an important predictor of PPGR, but dietary interventions to mitigate PPGR are not always successful. A personalized approach, considering behaviour and habitual pattern of glucose excursions assessed by continuous glucose monitor (CGM), may be more effective.

View Article and Find Full Text PDF

Background: Asian Indians are susceptible to developing type 2 diabetes at a lower age and often consume diets that are high in glycemic load and low in healthy fats.

Objectives: This study aimed to evaluate the effect of 30 g prebreakfast and 30 g predinner supplementation of pistachios for 12 wk on glycated hemoglobin (HbA1c), other glycemic markers, anthropometry, and lipid profile of Asian Indians with prediabetes.

Methods: In a 12-wk parallel arm, randomized controlled trial, we recruited 120 participants with prediabetes based on American Diabetes Association criteria.

View Article and Find Full Text PDF

Faecal calprotectin-based strategy for long-term monitoring of patients with Crohn's disease without or with mild endoscopic postoperative recurrence.

Dig Liver Dis

December 2024

Gastroentrology Department, Hospital Germans Trias i Pujol, 08916 Badalona, Catalonia, Spain; CIBEREHD, Madrid, Spain; Departament de Medicina, Universitat Autònoma de Barcelona, Catalonia, Spain. Electronic address:

Background: Endoscopic evaluation 6-12 months after ileocolonic resection (ICR) in Crohn's disease (CD) is advised to assess the development of postoperative recurrence (POR) but no further recommendations are available for long-term monitoring if no POR is noticed.

Methods: Prospective, open-label, study including asymptomatic patients with CD and ICR in whom no POR was observed at the last endoscopic evaluation. Patients were followed-up for two years and ileocolonoscopy was performed by means of a faecal calprotectin (FC)-based strategy.

View Article and Find Full Text PDF

A comprehensive review of non-invasive optical and microwave biosensors for glucose monitoring.

Biosens Bioelectron

December 2024

Programa de Pós-Graduação em Engenharia Elétrica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil; Departamento de Engenharia Eletrônica, Universidade Federal de Minas Gerais, Belo Horizonte, MG, 31270-901, Brazil. Electronic address:

Frequent glucose monitoring is essential for effective diabetes management. Currently, glucose monitoring is done using invasive methods such as finger-pricking and subcutaneous sensing. However, these methods can cause discomfort, heighten the risk of infection, and some sensing devices need frequent calibration.

View Article and Find Full Text PDF

Continuous Glucose Monitoring Underreports Blood Glucose During a Simulated Ultraendurance Run in Eumenorrheic Female Runners.

Int J Sports Physiol Perform

December 2024

Division of Health, Engineering, Computing and Science, Te Huataki Waiora School of Health, University of Waikato, Tauranga, New Zealand.

Purpose: Continuous-glucose-monitoring (CGM) sensors provide near-real-time glucose data and have been introduced commercially as a tool to inform nutrition decisions. The aim of this pilot study was to explore how factors such as the menstrual phase, extended running duration, and carbohydrates affect CGM outcomes among trained eumenorrheic females in an outdoor simulated ultraendurance running event.

Methods: Twelve experienced female ultrarunners (age 39 [6] y) participated in this crossover study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!