Untargeted metabolomics based on reverse phase LC-MS (RPLC-MS) plays a crucial role in biomarker discovery across physiological and disease states. Standardizing the development process of untargeted methods requires paying attention to critical factors that are under discussed or easily overlooked, such as injection parameters, performance assessment, and matrix effect evaluation. In this study, we developed an untargeted metabolomics method for plasma and fecal samples with the optimization and evaluation of these factors. Our results showed that optimizing the reconstitution solvent and sample injection amount was critical for achieving the balance between metabolites coverage and signal linearity. Method validation with representative stable isotopically labeled standards (SILs) provided insights into the analytical performance evaluation of our method. To tackle the issue of the matrix effect, we implemented a postcolumn infusion (PCI) approach to monitor the overall absolute matrix effect (AME) and relative matrix effect (RME). The monitoring revealed distinct AME and RME profiles in plasma and feces. Comparing RME data obtained for SILs through postextraction spiking with those monitored using PCI compounds demonstrated the comparability of these two methods for RME assessment. Therefore, we applied the PCI approach to predict the RME of 305 target compounds covered in our in-house library and found that targets detected in the negative polarity were more vulnerable to the RME, regardless of the sample matrix. Given the value of this PCI approach in identifying the strengths and weaknesses of our method in terms of the matrix effect, we recommend implementing a PCI approach during method development and applying it routinely in untargeted metabolomics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10921459PMC
http://dx.doi.org/10.1021/jasms.3c00418DOI Listing

Publication Analysis

Top Keywords

pci approach
16
untargeted metabolomics
12
metabolomics method
8
postcolumn infusion
8
plasma feces
8
matrix
7
method
6
rme
6
pci
5
development untargeted
4

Similar Publications

Background: There exists clinical equipoise regarding whether and when an invasive approach should be preferred over conservative treatment in the management of stable late ST-elevation myocardial infarction (STEMI) presenting within 12 to 72 h of symptom onset.

Objective: To perform a systematic review to identify the most effective treatment strategy between percutaneous coronary intervention (PCI) and medical therapy in stable late STEMI presenters by comparing their respective outcomes as well as determine the optimal timing of PCI by evaluating the outcomes of urgent versus non-urgent PCI approach in this patient population.

Methods: PubMed, Embase, and Cochrane databases were queried from inception until March 2024 for studies comparing the outcomes of PCI versus medical therapy, as well as urgent versus non-urgent PCI, in stable late STEMI patients presenting with symptom onset within 12-72 h.

View Article and Find Full Text PDF

Aims: This study aims to verify the feasibility and safety of percutaneous coronary intervention (PCI) after a distal transradial approach (dTRA) with radial artery occlusion (RAO) recanalization.

Methods: Between July 2018 and January 2022, 30 patients underwent PCI following attempted RAO recanalization via dTRA. Among these cases, the target radial arteries could not be recanalized in five patients, necessitating alternative vascular access.

View Article and Find Full Text PDF

Bone tissue, with its complex structure, often necessitates decalcification of the hard tissue for ex vivo morphological studies. The choice of a suitable decalcification method plays a crucial role in preserving desired features and ensuring compatibility with diverse imaging techniques. The search for a universal decalcification method that is suitable for a range of biophotonic analyses remains an ongoing challenge.

View Article and Find Full Text PDF

A new projector, Orthogonal-Distance Ray-tracer Varying-Full Width at Half Maximum (OD-RT-VF), was developed to model a shift-variant elliptical point-spread function (PSF) response to improve the image quality of a preclinical dual-rotation PET system. Approach: The OD-RT-VF projector models different FWHM values of the PSF in multiple directions, using half-height and half-width tube-of-response (ToR) values. The OD-RT-VF method's performance was evaluated against the original OD-RT method and a ToR model with constant response.

View Article and Find Full Text PDF

This clinical consensus statement of the European Association of Percutaneous Cardiovascular Interventions was developed in association with the European Society of Cardiology Working Group on Cardiovascular Surgery. It aims to define procedural and contemporary technical requirements that may improve the efficacy and safety of percutaneous coronary intervention (PCI), both in the acute phase and at long-term follow-up, in a high-risk cohort of patients on optimal medical therapy when clinical and anatomical high-risk criteria are present that entail unacceptable surgical risks, precluding the feasibility of coronary artery bypass grafting (CABG). This document pertains to patients with surgical contraindication according to the Heart Team, in whom medical therapy has failed (e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!