Strategies to detect Human African Trypanosomiasis (HAT) cases rely on serological screening of populations exposed to trypanosomes. In Guinea, mass medical screening surveys performed with the Card Agglutination Test for Trypanosomiasis have been progressively replaced by door-to-door approaches using Rapid Diagnostic Tests (RDTs) since 2016. However, RDTs availability represents a major concern and medical teams must often adapt, even in the absence of prior RDT performance evaluation. For the last 5 years, the Guinean HAT National Control Program had to combine three different RDTs according to their availability and price: the SD Bioline HAT (not available anymore), the HAT Sero-K-SeT (most expensive), and recently the Abbott Bioline HAT 2.0 (limited field evaluation). Here, we assess the performance of these RDTs, alone or in different combinations, through the analysis of both prospective and retrospective data. A parallel assessment showed a higher positivity rate of Abbott Bioline HAT 2.0 (6.0%, n = 2,250) as compared to HAT Sero-K-SeT (1.9%), with a combined positive predictive value (PPV) of 20.0%. However, an evaluation of Abbott Bioline HAT 2.0 alone revealed a low PPV of 3.9% (n = 6,930) which was surpassed when using Abbott Bioline HAT 2.0 in first line and HAT Sero-K-SeT as a secondary test before confirmation, with a combined PPV reaching 44.4%. A retrospective evaluation of all 3 RDTs was then conducted on 189 plasma samples from the HAT-NCP biobank, confirming the higher sensitivity (94.0% [85.6-97.7%]) and lower specificity (83.6% [76.0-89.1%]) of Abbott Bioline HAT 2.0 as compared to SD Bioline HAT (Se 64.2% [52.2-74.6%]-Sp 98.4% [94.2-99.5%]) and HAT Sero-K-SeT (Se 88.1% [78.2-93.8%]-Sp 98.4% [94.2-99.5%]). A comparison of Abbott Bioline HAT 2.0 and malaria-RDT positivity rates on 479 subjects living in HAT-free malaria-endemic areas further revealed that a significantly higher proportion of subjects positive in Abbott Bioline HAT 2.0 were also positive in malaria-RDT, suggesting a possible cross-reaction of Abbott Bioline HAT 2.0 with malaria-related biological factors in about 10% of malaria cases. This would explain, at least in part, the limited specificity of Abbott Bioline HAT 2.0. Overall, Abbott Bioline HAT 2.0 seems suitable as first line RDT in combination with a second HAT RDT to prevent confirmatory lab overload and loss of suspects during referral for confirmation. A state-of-the-art prospective comparative study is further required for comparing all current and future HAT RDTs to propose an optimal combination of RDTs for door-to-door active screening.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10906848 | PMC |
http://dx.doi.org/10.1371/journal.pntd.0011985 | DOI Listing |
Trop Med Int Health
December 2024
Department of Public Health, Institute of Tropical Medicine, Antwerp, Belgium.
Background: Rapid diagnostic tests for the serological detection of gambiense human African trypanosomiasis (gHAT) have been developed to overcome the limitations of the traditional screening method, CATT/T. b. gambiense.
View Article and Find Full Text PDFInfect Dis Poverty
July 2024
Intertryp, IRD-CIRAD-University of Montpellier, Montpellier, France.
Background: Serological screening tests play a crucial role to diagnose gambiense human African trypanosomiasis (gHAT). Presently, they preselect individuals for microscopic confirmation, but in future "screen and treat" strategies they will identify individuals for treatment. Variability in reported specificities, the development of new rapid diagnostic tests (RDT) and the hypothesis that malaria infection may decrease RDT specificity led us to evaluate the specificity of 5 gHAT screening tests.
View Article and Find Full Text PDFPLoS Negl Trop Dis
February 2024
Programme National de Lutte contre la Trypanosomiase Humaine Africaine, Ministère de la Santé, Conakry, Guinea.
Strategies to detect Human African Trypanosomiasis (HAT) cases rely on serological screening of populations exposed to trypanosomes. In Guinea, mass medical screening surveys performed with the Card Agglutination Test for Trypanosomiasis have been progressively replaced by door-to-door approaches using Rapid Diagnostic Tests (RDTs) since 2016. However, RDTs availability represents a major concern and medical teams must often adapt, even in the absence of prior RDT performance evaluation.
View Article and Find Full Text PDFInfect Dis Poverty
March 2023
UMR Intertryp IRD-CIRAD, French National Research Institute for Sustainable Development (IRD), University of Montpellier, Montpellier, France.
Background: Passive diagnosis of human African trypanosomiasis (HAT) at the health facility level is a major component of HAT control in Guinea. We examined which clinical signs and symptoms are associated with HAT, and assessed the performance of selected clinical presentations, of rapid diagnostic tests (RDT), and of reference laboratory tests on dried blood spots (DBS) for diagnosing HAT in Guinea.
Method: The study took place in 14 health facilities in Guinea, where 2345 clinical suspects were tested with RDTs (HAT Sero-K-Set, rHAT Sero-Strip, and SD Bioline HAT).
J Public Health Afr
September 2022
Organisation for Coordination of the Control of Endemic Diseases in Central Africa (OCEAC), Yaoundé, Cameroon.
Background: Case detection is essential for the management of human African trypanosomiasis (HAT), which is caused by i gambiense. Prior to parasitological confirmation, routine screening using the card agglutination test for trypanosomiasis (CATT) is essential. Recently, individual rapid diagnostic tests (RDTs) for the serodiagnosis of HAT have been developed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!