A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical Evaluation of an Artificial Intelligence-Based Decision Support System for the Diagnosis and American College of Radiology Thyroid Imaging Reporting and Data System Classification of Thyroid Nodules. | LitMetric

This study aimed to evaluate the clinical impact of an artificial intelligence (AI)-based decision support system (DSS), Koios DS, on the analysis of ultrasound imaging and suspicious characteristics for thyroid nodule risk stratification. A retrospective ultrasound study was conducted on all thyroid nodules with histological findings from June 2021 to December 2022 in a thyroid nodule clinic. The diagnostic performance of ultrasound imaging was evaluated by six readers on the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) before and after the use of the AI-based DSS and by AI itself. A total of 172 patients (83.1% women) with a mean age of 52.3 ± 15.3 years were evaluated. The mean maximum nodular diameter was 2.9 ± 1.2 cm, with 11.0% being differentiated thyroid carcinomas. Among the nodules initially classified as ACR TI-RADS 3 and 4, AI reclassified 81.4% and 24.5% into lower risk categories, respectively. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of the readers and the AI-based DSS versus histological diagnosis. There was an increase in the area under the ROC curve (AUROC) after the use of AI (0.776 vs. 0.817,  < 0.001). The AI-based DSS improved the mean sensitivity (Sens) (82.3% vs. 86.5%) and specificity (Spe) (38.3% vs. 54.8%), produced a high negative predictive value (94.5% vs. 96.4%), and increased the positive predictive value (PPV) (14.0% vs. 16.1%) and diagnostic precision (43.0% vs. 49.3%). Based on the ACR TI-RADS score, there was significant improvement in interobserver agreement after the use of AI ( = 0.741 for ultrasound imaging alone vs. 0.981 for ultrasound imaging and the AI-based DSS,  < 0.001). The use of an AI-based DSS was associated with overall improvement in the diagnostic efficacy of ultrasound imaging, based on the AUROC, as well as an increase in Sens, Spe, negative and PPVs, and diagnostic accuracy. There was also a reduction in interobserver variability and an increase in the degree of concordance with the use of AI. AI reclassified more than half of the nodules with intermediate ACR TI-RADS scores into lower risk categories.

Download full-text PDF

Source
http://dx.doi.org/10.1089/thy.2023.0603DOI Listing

Publication Analysis

Top Keywords

decision support
8
support system
8
american college
8
college radiology
8
radiology thyroid
8
thyroid imaging
8
imaging reporting
8
reporting data
8
data system
8
thyroid nodules
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!