A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An active derivatization detection method for inline monitoring the isolation of carbohydrates by preparative liquid chromatography. | LitMetric

Polysaccharides have unique physio-chemical properties and various biological functions and have rapidly expanded interest over the last two decades. The purification of polysaccharides and their degraded oligosaccharides is challenging because carbohydrates have no chromophore and need a proper detector to monitor the chromatographic elution process. This study proposed an active derivatization detection (ADD) method based on active splitting from post-column flow, a microchannel reactor for efficient derivatization of polysaccharide reducing sugars with p-hydroxybenzoic acid hydrazide, and in-line detection by the UV detector of liquid chromatography system. The method and device were validated by the use of 11 monosaccharides, sulfated oligosaccharides (from degraded carrageenan), and polysaccharides (from Zizania latifolia). It has shown much better performance than the traditional phenol-sulfuric acid method (gold standard). Moreover, the ADD module presumes an add-in to the original preparative LC system, independent of the scale of the purification process and type of system. The developed method is versatile for chromatographic separation of carbohydrates and lays the foundation for their subsequent studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2024.464730DOI Listing

Publication Analysis

Top Keywords

active derivatization
8
derivatization detection
8
liquid chromatography
8
method
5
detection method
4
method inline
4
inline monitoring
4
monitoring isolation
4
isolation carbohydrates
4
carbohydrates preparative
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!