A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Calibration of the coil constants and nonorthogonal angles of triaxial NMR coils based on in-situ EPR magnetometers. | LitMetric

Triaxial magnetic field coils are one of the most important components of magnetic resonance sensors. Traditional measurement methods for coil constants and non-orthogonal angles using fluxgate magnetometers are no longer suitable for small-volume nuclear magnetic resonance sensors. This study presents a method for measuring the coil constants and nonorthogonal angles of triaxial nuclear magnetic resonance coils using the dynamics of the electron paramagnetic resonance magnetometer without requiring any additional calibration equipment. After constructing the in-situ magnetometer, we measured the coil constants of the z- and the x-axes as 1189 nT/mA and 45.53 nT/mA, respectively. We obtained the nonorthogonal angle of approximately 0.18° between the z-axis and the x-y plane with a standard deviation of about 0.03° by solving the relevant trigonometric function. Additionally, the non-orthogonal angle between the x- and y-axes is approximately 1.70° with a standard deviation of about 0.17°. This study is significant for evaluating and reducing signal crosstalk errors and improving the accuracy of NMR sensors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2024.107634DOI Listing

Publication Analysis

Top Keywords

coil constants
16
magnetic resonance
12
constants nonorthogonal
8
nonorthogonal angles
8
angles triaxial
8
resonance sensors
8
nuclear magnetic
8
standard deviation
8
calibration coil
4
constants
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!