Introduction: The purpose of this study was to evaluate surgeons' ability to perform or supervise a standard operation with agreed-upon radiologic parameters after being on call.
Methods: We reviewed a consecutive series of patients with intertrochanteric hip fractures treated with a fixed angle device at 9 centers and compared corrected tip-apex distance and reduction quality for post-call surgeons versus those who were not. Subgroup analyses included surgeons who operated the night before versus not and attending-only versus resident involved cases. Secondary outcomes included union and perioperative complications.
Results: One thousand seven hundred fourteen patients were of average age 77 years. Post-call surgeons treated 823 patients and control surgeons treated 891. Surgical corrected tip-apex distance did not differ between groups: on-call 18 mm versus control 18 mm (P = 0.59). The Garden indices were 160° on the AP and 179° on the lateral in both groups. In 66 cases performed by surgeons who operated the night before, the TAD was 17 mm. No difference was noted in corrected tip-apex distance with and without resident involvement (P = 0.101). No difference was observed in pooled fracture-related complications (P = 0.23).
Conclusion: Post-call surgeons demonstrated no difference in quality and no increase in complications when performing hip fracture repair the next day compared with surgeons who were not on call.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10876225 | PMC |
http://dx.doi.org/10.5435/JAAOSGlobal-D-24-00016 | DOI Listing |
J Am Acad Orthop Surg Glob Res Rev
February 2024
From the Department of Orthopaedic Surgery, Boston University Medical Center, Boston, MA (Dr. Anderson, Dr. Sing, and Dr. Tornetta); the Department of Orthopaedic Surgery, University of Texas Health Sciences Center, Houston, TX (Dr. Pechero, Dr. Gary); the Department of Orthopaedic Surgery, Tufts Medical Center, Boston, MA (Dr. Hagar, Dr. Ryan); the Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY (Dr. Dvozhinskiy and Dr. Ricci); the Department of Orthopaedic Surgery, MetroHealth, Cleveland, OH (Ms. Fraifogl and Dr. Vallier); the Department of Orthopaedic Surgery, Indiana University Health, Indianapolis, IN (Dr. Fischer, Dr. Mullis); the Department of Orthopaedic Surgery, QEII Health Sciences Centre, Halifax Infirmary, Halifax, NS (Dr. Alqudhaya and Dr. Leighton); the Department of Orthopaedic Surgery, Geisinger Health, Pennsylvania, PA (Dr. Baig and Dr. Horwitz); and the Department of Orthopaedic Surgery, Beth Israel Lahey Health, Burlington, MA (Ms. Bramlett, Dr. Marcantonio).
Introduction: The purpose of this study was to evaluate surgeons' ability to perform or supervise a standard operation with agreed-upon radiologic parameters after being on call.
Methods: We reviewed a consecutive series of patients with intertrochanteric hip fractures treated with a fixed angle device at 9 centers and compared corrected tip-apex distance and reduction quality for post-call surgeons versus those who were not. Subgroup analyses included surgeons who operated the night before versus not and attending-only versus resident involved cases.
Eur J Trauma Emerg Surg
April 2024
Department of Orthopaedic Trauma and Reconstructive Surgery, University Hospital RWTH, Aachen, Germany.
Purpose: Although trochanteric fractures (TF) are a frequent event in the geriatric population, studies reporting on complication rates associated with surgical treatment are sparse. Thus, this study investigated the relevance of fracture-, implant-, and surgery-associated complications in TF. Furthermore, the role of possible risk factors for the before mentioned complications was investigated.
View Article and Find Full Text PDFNano Lett
February 2023
Department of Physics and Center for NanoScience, LMU Munich, Amalienstrasse 54, 80799Munich, Germany.
Atomic force microscopy (AFM) is a powerful technique for imaging molecules, macromolecular complexes, and nanoparticles with nanometer resolution. However, AFM images are distorted by the shape of the tip used. These distortions can be corrected if the tip shape can be determined by scanning a sample with features sharper than the tip and higher than the object of interest.
View Article and Find Full Text PDFMedicina (Kaunas)
November 2022
Department of Trauma Surgery, BG Unfallklinik Murnau, 82418 Murnau, Germany.
The aim of this study was to compare the effect of valgus versus anatomic reduction on internal fixation of Garden type III femoral neck fractures using the sliding hip screw (SHS) and anti-rotation screw (ARS) regarding the radiographic and therapeutic outcome. A retrospective case-controlled study was performed in a level I trauma center. All patients between 2006 and 2020 aged younger than 70 years with a Garden type III femoral neck fracture and a Kellgren-Lawrence score under grade III stabilized using SHS and ARS were identified.
View Article and Find Full Text PDFArch Orthop Trauma Surg
July 2023
Trauma Medical Center, Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, China.
Purpose: This study determined independent predictors and developed a predictive nomogram for failed correction of intertrochanteric fractures due to cut-out of the proximal femur nail anti-rotation (PFNA) device.
Methods: Demographic and radiological data of 592 adult patients with intertrochanteric fractures (AO 31A) treated by PFNA were collected retrospectively. Independent predictors of cut-out were obtained through univariate and multivariate analyses, and a predictive nomogram was established.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!