Background: Studies on the factors affecting vault after posterior chamber phakic Implantable Collamer Lens (ICL) have been carried out, but most of them are single-centered and subjective selections of parameters. The present study aimed to systematically analyze the factors for vault.
Methods: A systematic review of case series, case-control, and cohort studies derived from the articles published in PubMed, the Cochrane Library, Embase, Web of Science, CNKI, CBM, Wanfang and VIP, as well as ClinicalTrials, which were conducted to search for studies on factors of vault using four core terms: phakic intraocular lenses, vault, risk factor and observational study, from January 01, 1997, to February 20, 2023. The included studies were meta-analyzed quantitatively and described qualitatively. Subsequently, meta-regression and subgroup analysis were used.
Results: We identified 13 studies (1,607 subjects), and 14 factors were considered. Meta-analysis showed that anterior chamber depth (ACD), horizontal corneal white-to-white (hWTW), ICL-size, and age are dual effects of the abnormal vaults; anterior chamber volume (ACV) and lens thickness (LT) are a one-way effect; while axial length (AL), ICL- spherical equivalent (ICL-SE) and Km are insignificant. In addition, descriptive analysis of anterior chamber angle (ACA), horizontal sulcus to sulcus (hSTS), ciliary processes height (T value), crystalline lens rise (CLR), and gender showed that all factors except gender tend to have significant effects on vault. Sensitivity analysis showed stable combined results. Country and design respectively affect the heterogeneity in ACD and ICL-size at low vault, while design affects the heterogeneity in ACD at high vault. No publication bias exists.
Conclusions: Vault after ICL is related to multiple factors, especially anterior segmental biologic parameters, and they are weighted differently. We hope to provide a reference for the selection and adjustment of ICL.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10870571 | PMC |
http://dx.doi.org/10.1186/s12886-024-03325-9 | DOI Listing |
J Control Release
January 2025
Department of Pharmaceutical Sciences, College of Pharmacy, Robertson Life Sciences Building, Oregon State University, Portland, OR 97201, USA; Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR 97239, USA; Department of Biomedical Engineering, Robertson Life Sciences Building, Oregon Health & Science University, Portland, OR 97201, USA. Electronic address:
Lipid nanoparticles (LNPs) have shown great potential in the field of gene therapy for retinal diseases. To expand on this application, we investigated LNP-mediated mRNA delivery to the anterior chamber of the eye via the intracameral (IC) route of administration. Here, we show that IC injections of LNPs facilitated protein expression and gene editing in the trabecular meshwork (TM).
View Article and Find Full Text PDFBMJ Case Rep
January 2025
Ophthalmology, Shrewsbury and Telford Hospital NHS Trust, Shrewsbury, UK.
Approximately 3% of individuals in road traffic accidents suffer ocular injuries. We present a case of a man in his late 80s who presented with bilateral corneal decompensation following airbag deployment during a road traffic accident. Ocular examination revealed multilevel ocular injury with severe bilateral corneal oedema.
View Article and Find Full Text PDFOcul Immunol Inflamm
January 2025
Department of Ophthalmology,University of Health Sciences, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey.
Purpose: To evaluate the efficacy and safety of weekly adalimumab (ADA) treatment in non-infectious uveitis (NIU) patients, including both pediatric and adult populations, and identify factors influencing treatment efficacy.
Methods: A retrospective cohort study at two hospitals in Türkiye included 51 NIU patients (29 children, 22 adults) who escalated from bi-weekly to weekly ADA due to inadequate disease control. Data on six clinical parameters (anterior chamber reaction, vitreous haze, visual acuity, central macular thickness [CMT], prednisone use, uveitis flare-up frequency), adverse effects, and treatment-related factors were collected.
Pan Afr Med J
January 2025
Department of Ophthalmology, Faculty of Medicine Universitas Airlangga, Dr. Soetomo General Academic Hospital, Surabaya, Indonesia.
Anterior segment dysgenesis exerts its influence on a diverse array of ocular structures, encompassing the cornea, iris, ciliary body, anterior chamber and lens. We present a 20-month-old boy with bilateral corneal opacity. The visual acuity (VA) was 6/480 in both eyes.
View Article and Find Full Text PDFClin Ophthalmol
January 2025
Department of Ophthalmology, Saitama Medical Center, Saitama Medical University, Kawagoe-shi, Saitama, Japan.
Purpose: Among patients with angle-closure glaucoma, it is common to have a short-axial eye, which also makes it difficult to select an appropriate intraocular lens. Previous studies have focused on the ocular biometry of the long-axial eye, whereas only a few reports have focused on the short-axial eye. This study aimed to clarify the characteristics of the short-axial eye on ocular biometry among the elderly Japanese.