Evaluation of Intracardiac Pressures Using Subharmonic-aided Pressure Estimation with Sonazoid Microbubbles.

Radiol Cardiothorac Imaging

From the Departments of Radiology (C.E., P.M., F.F., J.K.D.), Medical Imaging and Radiation Sciences (M.E.M.), and Medicine (M.P.S., D.F., P.M., I.S.C., N.R., P.W., A.V., M.D.), Thomas Jefferson University, Philadelphia, Pa; Clarius Mobile Health, Vancouver, Canada (K.D.); and Department of Radiology, Mayo Clinic, Rochester, Minn (J.K.D).

Published: February 2024

Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta ( = 25) or RV ( = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants ( = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] ( = .85), 8.4 mm Hg ± 6.2 ( = .04), and 7.4 mm Hg ± 5.7 ( = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 ( ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10912883PMC
http://dx.doi.org/10.1148/ryct.230153DOI Listing

Publication Analysis

Top Keywords

pressure catheter
16
pressure
12
sonazoid microbubbles
12
shape technique
12
pressure measurements
12
subharmonic-aided pressure
8
pressure estimation
8
diastolic pressures
8
fluid-filled pressure
8
pressure catheters
8

Similar Publications

Introduction: Acute kidney injury (AKI) is a common complication of acute respiratory distress syndrome (ARDS) and multiple organ dysfunction syndrome (MODS) in patients receiving extracorporeal membrane oxygenation (ECMO) support, leading to requirement of continuous renal replacement therapy (CRRT) in 70% of ECMO patients. Parallel arrangement of CRRT and ECMO circuits is common in adult patients. However, CRRT may also be integrated directly into the ECMO circuit.

View Article and Find Full Text PDF

Global disparities in neurosurgical care necessitate innovations addressing affordability and accuracy, particularly for critical procedures like ventriculostomy. This intervention, vital for managing life-threatening intracranial pressure increases, is associated with catheter misplacement rates exceeding 30% when using a freehand technique. Such misplacements hold severe consequences including haemorrhage, infection, prolonged hospital stays, and even morbidity and mortality.

View Article and Find Full Text PDF

In hemodialysis patients, blood pressure (BP) measured at the postdialysis period (POSBP) can be used to diagnose hypertension. However, the optimal time point for POSBP remains uncertain. This cross-sectional study evaluated 210 long-term dialysis patients (66.

View Article and Find Full Text PDF

[Thrombectomy : Stent retriever vs aspiration].

Radiologie (Heidelb)

January 2025

Klinik für Diagnostische und Interventionelle Radiologie, Städtisches Klinikum Lüneburg, Bögelstraße 1, 21339, Lüneburg, Deutschland.

Besides intravenous thrombolysis, endovascular therapy (EVT) is also a standard treatment option for acute ischemic stroke. The clinical efficacy and safety of this procedure was proven in 2015 by several randomized controlled trials. The aim of EVT is to achieve the fastest possible recanalization of an occluded artery supplying the brain and, thus, reperfusion of the brain tissue.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!