Experimental and Modeled Assessment of Interventions to Reduce in a Residence during a Wildfire Event.

Pollutants

Maseeh College of Engineering and Computer Science, Portland State University, Portland, OR 97201, USA.

Published: March 2024

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality. We instrumented one residence for one week during an extreme wildfire event in the Pacific Northwest. Outdoor ambient concentrations of reached historic levels, sustained at over 200 μg/m for multiple days. Outdoor and indoor were monitored, and data regarding building characteristics, infiltration, and mechanical system operation were gathered to be consistent with the type of information commonly known for residential energy models. Two conditions were studied: a high-capture minimum efficiency rated value (MERV 13) filter integrated into a central forced air (CFA) system, and a CFA with MERV 13 filtration operating with a portable air cleaner (PAC). With intermittent CFA operation and no PAC, indoor corrected concentrations of reached 280 μg/m, and indoor/outdoor (I/O) ratios reached a mean of 0.55. The measured I/O ratio was reduced to a mean of 0.22 when both intermittent CFA and the PAC were in operation. Data gathered from the test home were used in a modeling exercise to assess expected I/O ratios from both interventions. The mean modeled I/O ratio for the CFA with an MERV 13 filter was 0.48, and 0.28 when the PAC was added. The model overpredicted the MERV 13 performance and underpredicted the CFA with an MERV 13 filter plus a PAC, though both conditions were predicted within 0.15 standard deviation. The results illustrate the ways that models can be used to estimate indoor concentrations in residences during extreme wildfire smoke events.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10863606PMC
http://dx.doi.org/10.3390/pollutants4010003DOI Listing

Publication Analysis

Top Keywords

merv filter
12
cfa merv
12
wildfire event
8
air quality
8
extreme wildfire
8
concentrations reached
8
intermittent cfa
8
i/o ratios
8
i/o ratio
8
cfa
6

Similar Publications

Classroom air quality in a randomized crossover trial with portable HEPA air cleaners.

J Expo Sci Environ Epidemiol

January 2025

Department of Environmental and Occupational Health, Joe C. Wen School of Population & Public Health, University of California, Irvine, CA, USA.

Background: Children living in communities with lower socioeconomic status and higher minority populations are often disproportionately exposed to particulate matter (PM) compared to children living in other communities.

Objective: We assessed whether adding HEPA filter air cleaners to classrooms with existing HVAC systems reduces indoor air pollution exposure.

Methods: From July 2022 to June 2023, using a block randomized crossover trial of 17 Los Angeles Unified School District elementary schools, classroom PM concentrations were monitored and compared for 99 classrooms with HEPA filter air cleaners and 87 classrooms with non-HEPA filter air cleaners.

View Article and Find Full Text PDF

Longevity of size-dependent particle removal performance of do-it-yourself box fan air filters.

Environ Sci Process Impacts

October 2024

Department of Civil and Environmental Engineering, University of California Davis, 1 Shields Avenue, Davis, CA, USA.

Filtration performance of do-it-yourself (DIY) box fan filters deployed across a university campus was assessed over an academic year. Four DIY air filters were constructed from box fans and air filters with a minimum efficiency reporting value (MERV) of 13 and deployed in four spaces (two laboratories that include sources of particles and two offices). They were operated 9 hours daily with a programmable timer and were continuously monitored with power meters.

View Article and Find Full Text PDF

Objectives: This study aimed to assess indoor air quality (IAQ) in long-term care facilities (LTCFs) in California during the COVID-19 pandemic and evaluate their implementation of IAQ best practices described by public health authorities to control respiratory pathogen transmission via inhalation.

Design: This observational study conducted IAQ assessments in a convenience sample of LTCFs to gather qualitative data on the implementation of IAQ best practices. The design included 5 pilot visits to develop a standardized method of data collection and then systematic data collection at 10 facilities.

View Article and Find Full Text PDF

Ventilation during COVID-19 in a school for students with intellectual and developmental disabilities (IDD).

PLoS One

April 2024

The Frederick J. and Marion A. Schindler Cognitive Neurophysiology Laboratory, The Ernest J. Del Monte Institute for Neuroscience, Department of Neuroscience, University of Rochester School of Medicine and Dentistry, Rochester, NY, United States of America.

Article Synopsis
  • * Researchers measured CO2 levels and air changes per hour (ACH) in 100 classrooms over 20 months, finding a significant link between high CO2 levels (≥1,000 ppm) and increased SARS-CoV-2 cases, although ACH alone didn't show a significant correlation.
  • * The results indicated that classrooms with MERV-13 filters had lower SARS-CoV-2 positivity rates, prompting ongoing improvements in the school’s ventilation systems to better safeguard student health.
View Article and Find Full Text PDF

Increasingly large and frequent wildfires affect air quality even indoors by emitting and dispersing fine/ultrafine particulate matter known to pose health risks to residents. With this health threat, we are working to help the building science community develop simplified tools that may be used to estimate impacts to large numbers of homes based on high-level housing characteristics. In addition to reviewing literature sources, we performed an experiment to evaluate interventions to mitigate degraded indoor air quality.