Introduction: To investigate the impact of prostatic shape observed on preoperative magnetic resonance imaging (MRI) on the difficulty of robot-assisted laparoscopic radical prostatectomy (RALP).
Methods: We retrospectively reviewed the operative records of 211 patients who underwent RALP. We excluded patients who received neoadjuvant therapy. All surgeries in this study were performed by two surgeons. Each patient clinicopathological and surgical data were reviewed. Prostate sphericity was evaluated by measuring the roundness of the prostate at the largest axial slice by MRI. The console time was adopted as an objective indicator for assessing surgical difficulty.
Results: The mean prostate volume was 34 cc (range 14-88) and the mean prostate roundness was 0.55 (range 0.24-0.90). The mean console time was 194 min (range 95-296). To assess the relationship between prostate volume and console time, scatter plot analysis was performed. The prostate volume had a weak positive correlation with the console time (r = .165, p = .016). Similarly, scatter plot analysis between the prostate roundness and console time demonstrated a weak positive correlation (r = .167, p = .015). Next, we performed subgroup analysis of 56 patients with a large prostate volume (≥40 cc), and the positive correlation between the prostate volume and the console time disappeared (r = .142, p = .296). On the other hand, the prostate roundness was more strongly correlated with the console time (r = .439, p = .001).
Conclusions: The spherical shape of the prostate is associated with the surgical difficulty of RALP, especially in patients with a large prostate volume.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/ases.13291 | DOI Listing |
Int J Behav Nutr Phys Act
January 2025
Department of Medicine, University of Otago, PO Box 56, Dunedin, 9010, New Zealand.
Background: Although evening screen time is thought to impair subsequent sleep, current measures are limited to questionnaires which seem unlikely to accurately assess screen time in youth. Given the ubiquitous nature of digital devices, improving measurement of screen time is required before related health effects can be appropriately determined. The aim of this study was to objectively quantify screen time before sleep using video camera footage.
View Article and Find Full Text PDFMedicina (Kaunas)
December 2024
Department of Obstetrics and Gynecology, Faculty of Medicine, Kagoshima University, Kagoshima 890-8520, Japan.
: This study aims to evaluate and compare the safety and efficacy of the da Vinci Xi and hinotori™ SRS robot-assisted surgical systems for gynecologic disorders. : We conducted a retrospective study of 401 cases (43 benign uterine tumors; 88 pelvic organ prolapses; 270 low-risk endometrial cancers) of robot-assisted surgery performed at Kagoshima University Hospital between January 2017 and October 2024. Surgical factors such as the operative time, blood loss, and complication rates were analyzed and compared between the da Vinci Xi (332 cases) and hinotori™ SRS (69 cases) systems.
View Article and Find Full Text PDFCureus
December 2024
Department of Emergency and Intensive Care Medicine, Hospital of the University of Occupational and Environmental Health, Fukuoka, JPN.
Objectives The objective of this study was to evaluate the occupational radiation exposure of healthcare workers during positron emission tomography (PET)/CT examinations, focusing on patient positioning and assessing the effectiveness of different radiation protection measures. Methods Thirteen medical workers (physicians, radiological technologists, and nurses) performed PET/CT examinations on 86 patients at a major Japanese hospital from June to August 2019. Occupational doses were measured using a real-time semiconductor dosimeter: RaySafe i2 (Unfors RaySafe, Billdal, Sweden), recording the 1 cm dose equivalent (Hp(10)).
View Article and Find Full Text PDFSurg Endosc
December 2024
Cedars-Sinai Medical Center, Los Angeles, CA, USA.
Introduction: The inability to sense force applied to tissue is suggested as a limitation to robotic-assisted surgery (RAS). This pre-clinical study evaluated the impact of a novel force feedback (FFB) technology, integrated on a next-generation robotic system that allows surgeons to sense forces exerted at the instrument tips, on suturing performance by novice surgeons during RAS.
Methods: Twenty-nine novice surgeons (< 50 RAS cases in the last 5 years) were randomized into two groups with (n = 15) or without (n = 14) FFB sensing.
Background: Robotic-assisted radical prostatectomy (RARP) is widely used as the main surgical approach to treat prostate cancer in the United States. Prostate size is often described as a factor affecting the outcomes of RARP as shown by many studies. However, these studies are limited to a small number of patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!