Introduction: Treating complex calcaneus fractures remains challenging. This study evaluated the influence of 3D printing and simulation on precision screw insertion into the calcaneus sustentaculum tali (ST).
Hypothesis: 3D printing and simulation improve the treatment for calcaneal fracture.
Patients And Methods: This retrospective cohort study included 85 patients admitted with 93 Sanders type II-IV intra-articular fractures from January 2015 to June 2020. Multi-slice computed tomography (MSCT) images were used in the conventional group, and MSCT data were used to construct a 3D model of the calcaneus to simulate screw insertion and verify parameter accuracy in the 3D group.
Results: The designed parameters (upward and backward oblique angles and screw-path length) were similar to the actual values in the 3D group (p=0.428,0.287,0.585) but not in the conventional group (p=0.01,0.002,0.023). The Maryland foot functional score, accuracy rate, and average screw number were higher and operative time was shorter in the 3D group (p=0.005,0.007,0.000,0.000).
Discussion: Preoperative simulation using the 3D printing model helped guide the screws into the ST more accurately, lending better-quality treatment for Sanders type II-IV calcaneal fractures.
Level Of Proof: III; Retrospective case-control study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2024.103835 | DOI Listing |
Oper Orthop Traumatol
January 2025
Klinik für Unfall‑, Hand und Wiederherstellungschirurgie, Universitätsmedizin Rostock, Schillingallee 35, 18057, Rostock, Deutschland.
Objective: Treatment with transcutaneous osseointegrated prosthesis systems (TOPS) for short femoral amputation stumps aims to restore independent walking ability after proximal femoral amputation by direct bone-guided prosthesis anchorage. This cannot be safely achieved with conventional socket prostheses due to the mechanically inadequate socket contact surface.
Indications: Treatment of patients with short transfemoral stumps who cannot be mobilized sufficiently with conventional socket prostheses.
J Neurosurg Case Lessons
January 2025
Department of Neurosurgery, Faculty of Medicine, Azad Tehran University of Medical Sciences, Tehran, Iran.
Background: Pedicle screw insertion in posterior spinal surgery can cause vascular injuries, including rare intercostal artery pseudoaneurysms, which are typically discovered incidentally during reimaging. Onyx embolization is an effective treatment for small artery pseudoaneurysms.
Observations: A 36-year-old man who had initially presented with back pain that remained unresponsive to nonsteroidal anti-inflammatory drugs was diagnosed with a T7-8 sarcomatous lesion confirmed by magnetic resonance imaging and biopsy.
Acta Bioeng Biomech
September 2024
Department of Mechanics, Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Wrocław University of Science and Technology, Wrocław, Poland.
: The aim of this study was to evaluate the abrasive wear of the sliding screw-rod joint used in growth guidance system (GGS) stabilizers, allowing for the translation of the screw along the rod during the spinal growth process in a standard and modified system. : The study used single kinematic screw-rod pairs made of titanium alloy Ti6Al4V. Mechanical tests (cyclic loads) simulated the stabilizer's operation under conditions similar to actual use.
View Article and Find Full Text PDFJ Foot Ankle Surg
January 2025
Enovis Foot & Ankle, Atlanta, GA; Georgia Institute of Technology, Atlanta, GA. Electronic address:
Orthopedic screws are widely used to achieve bone reduction, compression, and construct stability. However, the relationship between insertion torque, interfragmentary compression, and fixation strength, especially when comparing standard screws with NiTiNOL/sustained dynamic compression (SDC), has not been thoroughly investigated. This study measured insertion torque, interfragmentary compression, and fixation strength for two types of headed orthopedic devices-standard and SDC-using solid foam bone replicates and cadaver validation.
View Article and Find Full Text PDFChin J Traumatol
January 2025
Department of Emergency Surgery and Orthopaedic Surgery, Qilu Hospital of Shandong University, Jinan, 250012, China. Electronic address:
Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.