AI Article Synopsis

  • Researchers are exploring the use of external actuation to navigate drug-eluting microrobots in the bloodstream for more targeted drug delivery in cancer treatment.
  • An algorithm was developed to optimize patient positioning based on gravity, enhancing the navigation of magnetic microrobots (MMRs) through the liver arteries in pigs.
  • The results showed a significant increase in the delivery efficiency of MMRs to liver lobes, indicating this technique could improve treatment for patients with liver cancer.

Article Abstract

Using external actuation sources to navigate untethered drug-eluting microrobots in the bloodstream offers great promise in improving the selectivity of drug delivery, especially in oncology, but the current field forces are difficult to maintain with enough strength inside the human body (>70-centimeter-diameter range) to achieve this operation. Here, we present an algorithm to predict the optimal patient position with respect to gravity during endovascular microrobot navigation. Magnetic resonance navigation, using magnetic field gradients in clinical magnetic resonance imaging (MRI), is combined with the algorithm to improve the targeting efficiency of magnetic microrobots (MMRs). Using a dedicated microparticle injector, a high-precision MRI-compatible balloon inflation system, and a clinical MRI, MMRs were successfully steered into targeted lobes via the hepatic arteries of living pigs. The distribution ratio of the microrobots (roughly 2000 MMRs per pig) in the right liver lobe increased from 47.7 to 86.4% and increased in the left lobe from 52.2 to 84.1%. After passing through multiple vascular bifurcations, the number of MMRs reaching four different target liver lobes had a 1.7- to 2.6-fold increase in the navigation groups compared with the control group. Performing simulations on 19 patients with hepatocellular carcinoma (HCC) demonstrated that the proposed technique can meet the need for hepatic embolization in patients with HCC. Our technology offers selectable direction for actuator-based navigation of microrobots at the human scale.

Download full-text PDF

Source
http://dx.doi.org/10.1126/scirobotics.adh8702DOI Listing

Publication Analysis

Top Keywords

navigation magnetic
12
magnetic microrobots
8
hepatic arteries
8
magnetic resonance
8
magnetic
5
microrobots
5
human-scale navigation
4
microrobots hepatic
4
arteries external
4
external actuation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!