Communication from automated vehicles (AVs) to pedestrians using augmented reality (AR) could positively contribute to traffic safety. However, previous AR research for pedestrians was mainly conducted through online questionnaires or experiments in virtual environments instead of real ones. In this study, 28 participants conducted trials outdoors with an approaching AV and were supported by four different AR interfaces. The AR experience was created by having participants wear a Varjo XR-3 headset with see-through functionality, with the AV and AR elements virtually overlaid onto the real environment. The AR interfaces were vehicle-locked (), world-locked (, ), or head-locked (). Participants had to hold down a button when they felt it was safe to cross, and their opinions were obtained through rating scales, interviews, and a questionnaire. The results showed that participants had a subjective preference for AR interfaces over no AR interface. Furthermore, the was more effective than no AR interface in a statistically significant manner, as it led to participants more frequently keeping the button pressed. The scored lower than the other interfaces, presumably due to low saliency and the fact that participants had to visually identify both this AR interface and the AV. In conclusion, while users favour AR in AV-pedestrian interactions over no AR, its effectiveness depends on design factors like location, visibility, and visual attention demands. In conclusion, this work provides important insights into the use of AR outdoors. The findings illustrate that, in these circumstances, a clear and easily interpretable AR interface is of key importance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10861735 | PMC |
http://dx.doi.org/10.3389/frobt.2024.1324060 | DOI Listing |
Clin Nucl Med
December 2024
From the Department of Nuclear Medicine, Saarland University-Medical Center, Homburg, Germany.
Background: Even though the introduction of 177Lu-PSMA-617 RLT represents a major milestone in the treatment of mCRPC, there are still patients who do not respond adequately to this therapy and for whom there are only limited options left. Augmenting 177Lu-PSMA-617 RLT with the alpha-emitter 225Ac-PSMA-617 may present an escalating treatment option to increase efficacy. In this study, we aim to evaluate outcome and safety of 225Ac-PSMA-617 augmentation to 177Lu-PSMA-617 RLT in patients who present insufficient response to monotherapy with 177Lu-PSMA-617 RLT.
View Article and Find Full Text PDFJ Vis
January 2025
Magic Leap Switzerland GmbH, Zürich, Switzerland.
When rendering the visual scene for near-eye head-mounted displays, accurate knowledge of the geometry of the displays, scene objects, and eyes is required for the correct generation of the binocular images. Despite possible design and calibration efforts, these quantities are subject to positional and measurement errors, resulting in some misalignment of the images projected to each eye. Previous research investigated the effects in virtual reality (VR) setups that triggered such symptoms as eye strain and nausea.
View Article and Find Full Text PDFAesthetic Plast Surg
January 2025
Department of Craniomaxillofacial Surgery, Plastic Surgery Hospital, CAMS&PUMC (Chinese Academy of Medical Sciences and Peking Union Medical College), Beijing, 100144, China.
Background: Bibliometric analyses of software applications in plastic surgery are relatively limited. This study aims to address this gap by summarizing current research trends and providing insights that may guide future developments in this field.
Methods: Data were retrieved from the Web of Science Core Collection.
Adv Sci (Weinh)
January 2025
Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, 37673, Republic of Korea.
The commercialization of metasurfaces is crucial for real-world applications such as wearable sensors, pigment-free color pixels, and augmented and virtual reality devices. Nanoparticle-embedded resin-based nanoimprint lithography (PER-NIL) has shown itself to be a low-cost, high-throughput manufacturing method enabling the replication of high-index nanostructures. It has been extensively integrated into the fabrication of hologram metasurfaces, metalenses, and sensors due to its procedural simplicity.
View Article and Find Full Text PDFJ Robot Surg
January 2025
Multimedia University, Cyberjaya, Malaysia.
Artificial intelligence and robotics are revolutionizing surgical practices by enhancing precision, efficiency, and patient outcomes. With global healthcare systems increasingly adopting AI-driven technologies, the integration of robotics in surgery addresses critical challenges such as surgical accuracy, minimally invasive techniques, and healthcare accessibility. However, disparities in access and ethical concerns regarding automation persist globally, necessitating a balanced discourse on these advancements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!