Calibration improvements expand filterscope diagnostic use.

Rev Sci Instrum

Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA.

Published: February 2024

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure Dα emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure Dβ, Dγ, W-I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma-wall interactions. It also enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0175421DOI Listing

Publication Analysis

Top Keywords

filterscope diagnostic
8
visible light
8
light emission
8
emission plasma
8
spectroscopic diagnostics
8
calibration improvements
4
improvements expand
4
filterscope
4
expand filterscope
4
diagnostic filterscope
4

Similar Publications

Calibration improvements expand filterscope diagnostic use.

Rev Sci Instrum

February 2024

Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA.

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm.

View Article and Find Full Text PDF

The present work concerns the measurements obtained with the Tungsten (W) Environment in Steady-state Tokamak (WEST) visible spectroscopy system during the first experimental campaign. This system has been developed in the framework of the WEST project that equipped the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFC) in view of preparing for ITER operation. The goal of this diagnostic is to measure the PFC sources and the deuterium recycling with spectral, spatial, and temporal resolution adapted to the predicted power deposition profiles on the objects observed.

View Article and Find Full Text PDF

Filterscope diagnostic system on the Experimental Advanced Superconducting Tokamak (EAST).

Rev Sci Instrum

November 2016

General Atomics, San Diego, California 92186-5608, USA.

A filterscope diagnostic system has been mounted to observe the line emission and visible bremsstrahlung emission from plasma on the experimental advanced superconducting tokamak during the 2014 campaign. By this diagnostic system, multiple wavelengths including D (656.1 nm), D (433.

View Article and Find Full Text PDF

Development of visible spectroscopy diagnostics for W sources assessment in WEST.

Rev Sci Instrum

November 2016

CEA, IRFM, F-13108 Saint-Paul-Lez-Durance, France.

The present work concerns the development of a W sources assessment system in the framework of the tungsten-W environment in steady state tokamak project that aims at equipping the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFCs) in view of preparing ITER operation. The goal is to assess W sources and D recycling with spectral, spatial, and temporal resolution adapted to the PFCs observed. The originality of the system is that all optical elements are installed in the vacuum vessel and compatible with steady state operation.

View Article and Find Full Text PDF

Spectroscopic imaging of limiter heat and particle fluxes and the resulting impurity sources during Wendelstein 7-X startup plasmas.

Rev Sci Instrum

November 2016

Max-Planck-Institut für Plasma Physik, Wendelsteinstrasse 1, 17491 Greifswald, Germany.

A combined IR and visible camera system [G. A. Wurden et al.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!