NEMA NU 2-2018 evaluation and image quality optimization of a new generation digital 32-cm axial field-of-view Omni Legend PET-CT using a genetic evolutionary algorithm.

Biomed Phys Eng Express

The Wales Research and Diagnostic Positron Emission Tomography Imaging Centre, Cardiff University, School of Medicine, Cardiff, CF14 4XN, Wales, United Kingdom.

Published: February 2024

A performance evaluation was conducted on the new General Electric (GE) digital Omni Legend PET-CT system with 32 cm extended field of view. The first commercially available clinical digital bismuth germanate system. The system does not use time of flight (ToF). Testing was performed in accordance with the NEMA NU2-2018 standard. A comparison was made between two other commercial GE scanners with extended fields of view; the Discovery MI - 6 ring (ToF enabled) and the Discovery IQ (non-ToF). A genetic evolutionary algorithm was developed to optimize image reconstruction parameters from image quality assessments. The Omni demonstrated average spatial resolutions at 1 cm radial offset as 3.9 mm FWHM. The total system sensitivity at the center was 44.36 cps/kBq. The peak NECR was measured as 501 kcps at 17.8 kBq mlwith a 35.48% scatter fraction. The maximum count-rate error below NECR peak was 5.5%. Using standard iterative reconstructions, sphere contrast recovery coefficients were from 52.7 ± 3.2% (10 mm) to 92.5 ± 2.4% (37 mm). The PET-CT co-registration accuracy was 2.4 mm. In place of ToF, the Omni employs software corrections through a pre-trained neural network (PDL) (trained on non-ToF to ToF) that takes Bayesian penalized likelihood reconstruction (Q.Clear) images as input. The optimum parameters for image reconstruction, determined using the genetic algorithm were a Q.Clear parameter,, of 350 and a 'medium' PDL setting. Using standard iterative reconstructions, the Omni initially showed increased background variability compared to the Discovery MI. With optimized PDL reconstruction parameters selected using the genetic algorithm the performance of the Omni surpassed that of the Discovery MI on all NEMA tests. The genetic algorithm's demonstrated ability to enhance image quality in PET-CT imaging underscores the importance of algorithm driven optimization and underscores the requirement to validate its use in the clinical setting.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/ad286cDOI Listing

Publication Analysis

Top Keywords

image quality
12
omni legend
8
legend pet-ct
8
genetic evolutionary
8
evolutionary algorithm
8
algorithm performance
8
image reconstruction
8
reconstruction parameters
8
parameters image
8
standard iterative
8

Similar Publications

Research progress of femoral head necrosis in HIV-infected patients.

Ann Med

December 2025

Department of Joint and Sports Medicine, Zhongnan Hospital, Wuhan University, Wuhan, China.

As life expectancy among patients infected with the human immunodeficiency virus (HIV) increases, a growing number of complications have been observed. This population displays an elevated risk of ischemic necrosis of the femoral head in comparison to the general population, which may be attributed to HIV infection, antiretroviral medication use, and hormone application. Patients infected with the human immunodeficiency virus (HIV) who also have necrosis of the femoral head tend to present at an earlier age, with a rapid disease progression and a high incidence of bilateral onset.

View Article and Find Full Text PDF

Importance: Airway stenosis is a rare but debilitating disorder that significantly degrades the quality of life in affected patients. Treatments are primarily surgical, and disease management lacks established medical therapies. The North American Airway Collaborative held its third symposium at The Johns Hopkins Hospital in Baltimore, Maryland, on April 15, 2024, focused on strategies to advance the care of these patients.

View Article and Find Full Text PDF

Purpose: MMQ1 is a Danish-language patient-reported outcome measure (PROM) for quality of life (QOL) in people with multiple long-term conditions (MLTC). It measures needs-based QOL across six scales: Physical ability, Concerns and worries, Limitations in daily life, Social life, Personal finances and Self-image. There is currently no such measure available in English.

View Article and Find Full Text PDF

Since the adoption of neoadjuvant chemoradiation and total mesorectal excision as the standard in rectal cancer care, there has been marked improvement in the local recurrence rates. In this context, restaging magnetic resonance imaging (MRI) plays a key role in the assessment of tumor response, occasionally enabling organ-sparing approaches. However, the role of restaging MRI in evaluating lateral lymph nodes remains limited.

View Article and Find Full Text PDF

Positron emission tomography (PET) imaging plays a pivotal role in oncology for the early detection of metastatic tumors and response to therapy assessment due to its high sensitivity compared to anatomical imaging modalities. The balance between image quality and radiation exposure is critical, as reducing the administered dose results in a lower signal-to-noise ratio (SNR) and information loss, which may significantly affect clinical diagnosis. Deep learning (DL) algorithms have recently made significant progress in low-dose (LD) PET reconstruction.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!