A self-stiffening compliant intracortical microprobe.

Biomed Microdevices

School of Engineering, Deakin University, Geelong, VIC, 3216, Australia.

Published: February 2024

Utilising a flexible intracortical microprobe to record/stimulate neurons minimises the incompatibility between the implanted microprobe and the brain, reducing tissue damage due to the brain micromotion. Applying bio-dissolvable coating materials temporarily makes a flexible microprobe stiff to tolerate the penetration force during insertion. However, the inability to adjust the dissolving time after the microprobe contact with the cerebrospinal fluid may lead to inaccuracy in the microprobe positioning. Furthermore, since the dissolving process is irreversible, any subsequent positioning error cannot be corrected by re-stiffening the microprobe. The purpose of this study is to propose an intracortical microprobe that incorporates two compressible structures to make the microprobe both adaptive to the brain during operation and stiff during insertion. Applying a compressive force by an inserter compresses the two compressible structures completely, resulting in increasing the equivalent elastic modulus. Thus, instant switching between stiff and soft modes can be accomplished as many times as necessary to ensure high-accuracy positioning while causing minimal tissue damage. The equivalent elastic modulus of the microprobe during operation is ≈ 23 kPa, which is ≈ 42% less than the existing counterpart, resulting in ≈ 46% less maximum strain generated on the surrounding tissue under brain longitudinal motion. The self-stiffening microprobe and surrounding neural tissue are simulated during insertion and operation to confirm the efficiency of the design. Two-photon polymerisation technology is utilised to 3D print the proposed microprobe, which is experimentally validated and inserted into a lamb's brain without buckling.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10861748PMC
http://dx.doi.org/10.1007/s10544-024-00700-7DOI Listing

Publication Analysis

Top Keywords

microprobe
12
intracortical microprobe
12
tissue damage
8
compressible structures
8
equivalent elastic
8
elastic modulus
8
brain
5
self-stiffening compliant
4
compliant intracortical
4
microprobe utilising
4

Similar Publications

Fiber-Optic Photoacoustic Gas Microprobe Based on Linear Spot-Type Multipass Cell.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.

A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm.

View Article and Find Full Text PDF

Chemical weathering of lithologies with high geochemical backgrounds such as black shale has been proposed to be a critical source for toxic elements in soil and water systems. However, mechanisms controlling the release, migration and enrichment of toxic elements during black shale weathering are poorly understood. This study utilized a suite of micro analytical techniques such as TESCAN integrated mineral analyzer (TIMA), scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS), X-ray photoelectron spectroscopy (XPS) and electron micro-probe analysis (EMPA) to elucidate the intimate relationship between mineralogical transformations and elemental behaviors from profile scale to mineral scale.

View Article and Find Full Text PDF

A microporous zincophosphate with the idealized formula NaZn[Zn(PO)] was obtained through high-temperature hydrothermal synthesis and characterized by scanning electron microscopy, microprobe analysis and X-ray diffraction. The orthorhombic compound, which crystallizes in acentric space group Pna2 with unit-cell parameters a = 12.9901 (2), b = 16.

View Article and Find Full Text PDF

The Apollo 17 73001/73002 double drive tube, collected at the base of the South Massif in the Taurus-Littrow Valley, was opened in 2019 as part of the Apollo Next Generation Sample Analysis program (ANGSA). A series of continuous thin sections were prepared capturing the full length of the upper portion of the double drive tube (73002). The aim of this study was to use Quantitative Evaluation of Minerals by SCANing electron microscopy (QEMSCAN), to search for clasts of non-lunar meteoritic origin and to analyze the mineralogy and textures within the core.

View Article and Find Full Text PDF

A full characterization of multilayer ceramic capacitors including variations in capacitance, series resistance, and series inductance is accomplished by measuring their RF response while being submitted to mechanical stress. This allows for the first time quantifying the degradation of the device's RF performance when cracks form within its structure. In this regard, the main challenge is designing an interface for measuring the high-frequency response of a capacitor using a vector network analyzer as a bending test on a PCB in progress, which is achieved here by using a microstrip-based test fixture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!