Neonatologist Performed Echocardiography (NPE) is one of the emerging technologies used to evaluate Systemic Blood Flow (SBF) in term and preterm infants. Right Ventricular Output (RVO) can assess SBF correctly in the absence of significant interatrial or interventricular shunts, even in the presence of a large patent ductus arteriosus (PDA), but only few studies evaluated inter-observer variability in neonates. Furthermore, measuring pulmonary peak flow (PF) provides a simple screening tool for low SBF state, easier and faster to perform than RVO; no previous studies evaluated PF inter-observer variability. To describe inter-observer variability of RVO and PF measurement in neonates. We conducted a prospective observational study in term and preterm infants admitted to the Neonatal Intensive Care Unit (NICU). Echocardiographic examinations were performed by two expert neonatologists, blinded to each other. Recordings were analyzed off-line to assess RVO and PF variability between observers. We analyzed a cohort of 33 neonates, 17 of them born prematurely. Inter-observer mean difference for RVO was 22,1 mL/kg/min (p = 0.005); the biggest discrepancy was due to pulmonary valve diameter measurement (p = 0.0001). Inter-observer mean difference for PF measurement was not statistically significant. We found a statistically significant inter-observer variability for RVO measurement, consistent with previous reports; PF instead showed low inter-observer variability. For this reason, PF could be evaluated in future studies as a surrogate for RVO in both term and preterm infants, especially in emergency conditions or in presence of a poor echocardiographic window.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-024-03066-2DOI Listing

Publication Analysis

Top Keywords

inter-observer variability
24
term preterm
12
preterm infants
12
inter-observer
8
ventricular output
8
observational study
8
studies evaluated
8
evaluated inter-observer
8
variability rvo
8
rvo measurement
8

Similar Publications

The flow convergence method includes calculation of the proximal isovelocity surface area (PISA) and is widely used to classify mitral regurgitation (MR) with echocardiography. It constitutes a primary decision factor for determination of treatment and should therefore be a robust quantification method. However, it is known for its tendency to underestimate MR and its dependence on user expertise.

View Article and Find Full Text PDF

Background: High-quality assessment of prostate MRI is fundamental in both clinical practice and screening. There is a lack of national level data on variability in prostate volume measurement and PI-RADS assessment. Methods of quality assurance need to be developed.

View Article and Find Full Text PDF

Background: The aim of this study was to evaluate the correlation of the volume and minimum axial area (MAA) measurements between different upper and lower boundaries used for oropharyngeal airway assessment.

Methods: Cone Beam Computed Tomography (CBCT) scans of 49 subjects taken for pre-orthognathic surgical planning were obtained retrospectively from the archives (n = 49; 32 females, 17 males; mean age = 20.9 ± 5.

View Article and Find Full Text PDF

Background: Specific pelvic bone dimensions have been identified as predictors of total mesorectal excision (TME) difficulty and outcomes. However, manual measurement of these dimensions (pelvimetry) is labor intensive and thus, anatomic criteria are not included in the pre-operative difficulty assessment. In this work, we propose an automated workflow for pelvimetry based on pre-operative magnetic resonance imaging (MRI) volumes.

View Article and Find Full Text PDF

Objective: To test the reliability of the Outcome Measures in Rheumatology Giant cell arteritis (GCA) Ultrasonography Score (OGUS) and other composite scores in a patient-based exercise involving experts and non-experts in vascular ultrasonography.

Methods: Six GCA patients were scanned twice (two rounds separated ≥3 hours) by 12 experts and 12 non-experts. Non-experts received 90 min of theoretical and 240 min of practical training between rounds 1 and 2.

View Article and Find Full Text PDF