AI Article Synopsis

  • - The study aimed to predict stages of liver fibrosis and necroinflammation using various ultrasound measurements, specifically 2D shear wave elastography (2D-SWE), transient elastography (Fibroscan), and shear wave dispersion (SWD).
  • - Significant findings showed that 2D-SWE and TE effectively detected different stages of hepatic fibrosis, with specific cutoff values leading to reliable categorizations, while SWD was useful for identifying levels of necroinflammation.
  • - The conclusion emphasizes that both 2D-SWE and TE provide a noninvasive means to assess liver damage stages, with SWD being beneficial for detecting inflammation in the liver.

Article Abstract

Objective: Our aim was to predict these stages of hepatic fibrosis and necroinflammation using measurements from two-dimensional shear wave elastography (2D-SWE), transient elastography (Fibroscan, TE), and shear wave dispersion (SWD).

Materials And Methods: In this prospectively designed study, chronic liver patients with nonspecific etiology whose biopsy was performed for up to 1 week were included. Two-dimensional SWE, SWD, and TE measurements were performed. The METAVIR and F-ISHAK classification was used for histopathological evaluation.

Results: Two-dimensional SWE and TE were considered significant for detecting hepatic fibrosis. In distinguishing ≥F2, for 2D-SWE, area under the receiver operating characteristics (AUROC) was 0.86 (confidence interval [CI], 0.75-0.96) for the cutoff value of 8.05 kPa ( P = 0.003); for TE, AUROC was 0.79 (CI, 0.65-0.94) for the cutoff value of 10.4 kPa ( P < 0.001). No significance was found for TE in distinguishing ≥F3 ( P = 0.132). However, for 2D-SWE, a cutoff value of 10.45 kPa ( P < 0.001), with AUROC = 0.87 (CI, 0.78-0.97) was determined for ≥F3. Shear wave dispersion was able to determine the presence of necroinflammation ( P = 0.016) and a cutoff value of 15.25 (meter/second)/kiloHertz ([m/s]/kHz) ( P = 0.006) and AUROC of 0.71 (CI, 0.57-0.85) were calculated for distinguishing ≥A2. In addition, a cutoff value of 17.25 (m/s)/kHz ( P = 0.023) and AUROC = 0.72 (CI, 0.51-0.93) were found to detect severe necroinflammation. The cutoff value for SWD was 15.25 (m/s)/kHz ( P = 0.013) for detecting ≥A2 in the reversible stage of fibrosis (F0, F1, and F2), and AUROC = 0.72 (CI, 0.56-0.88).

Conclusions: Two-dimensional SWE and TE measurements were significant in detecting the irreversible stage and the stage that should be treated in hepatic fibrosis noninvasively. Shear wave dispersion measurements were significant in detecting necroinflammation noninvasively.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RUQ.0000000000000677DOI Listing

Publication Analysis

Top Keywords

shear wave
24
wave dispersion
16
hepatic fibrosis
12
two-dimensional swe
12
fibroscan shear
8
wave elastography
8
dispersion measurements
8
fibrosis necroinflammation
8
kpa 0001
8
auroc 072
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!