A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A visualization method for quickly detecting nitrite ions in breath condensate using a portable closed bipolar electrochemical sensor. | LitMetric

A portable and non-invasive sensor presents an innovative way to measure inflammation biomarkers in exhaled breath condensate (EBC). This research is focused on developing a miniaturized bipolar electrochemical sensor that can be connected to a smartphone app. This device will be able to detect adding known amounts of nitrite (spikes) to a salt solution and small amounts of nitrite ions in collected real samples in EBC. The sensor was fabricated and tested for its rapid electron transfer capability and ability to detect nitrite ions even at very low concentrations and low real sample levels. In the proposed setup, when the required potential was applied by using a direct power supply, the nitrite ions were oxidized electrocatalytically at amine-functionalized graphene oxide (AGO) decorated with gold nanoparticles on a carbon paper anodic pole. On the other hand, the reduction reaction of Prussian blue occurred at the cathodic pole of the bipolar electrode simultaneously. This strategy led to a change in color from blue to white as a result of the reduction process and the color change is proportional to the concentration of nitrite ions in the analytical solution. The combination of smartphones with the colorimetric method has resulted in a platform for the detection of test strips that is more visual and convenient. The amperometry and voltammetric methods of nitrite detection showed a linear range of up to 1230 μM. The bipolar electrochemical sensor was able to detect the clinically relevant range of nitrite from 0.5 to 85 μM in a buffer with an ultralow detection limit (LOD) of 250 nM (S/N = 3), fast response and excellent selectivity. It was benchmarked by utilizing pre-characterized real EBC samples to differentiate patients with respiratory diseases from healthy volunteers. By tracking the results of nitrite measurements over time, it has become possible to detect trends and changes in an individual's nitrite ion concentration and to potentially identify lung inflammation earlier.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3an01676eDOI Listing

Publication Analysis

Top Keywords

nitrite ions
20
bipolar electrochemical
12
electrochemical sensor
12
nitrite
10
breath condensate
8
amounts nitrite
8
ions
5
sensor
5
visualization method
4
method detecting
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!